Description of the machine

Additional display with selector button

Selector button “Residual moisture” /
“Time” / “Vented air”

“Residual moisture” (%)
With this button the programmed residual

moisture values in programmes 

1

 to 

9

 can

be altered.

“Time” (h/mins)
With this button the programme duration can

be changed in programme 

0

  (003 minutes

to 1.00 hour), and in programme 

!

  (003 min-

utes to 3.00 hours).

- These changes can only be carried out be-
fore the start of the programme.  Changes are
only valid each time for one selected pro-
gramme.  At the end of the programme the val-
ues set revert to the standard values. -

“Temperature of vented air” (

o

C)

If the button is pressed in while a programme
is running and released immediately, the cur-
rent vented air temperature will show in the ad-
ditional display for approx. 5 seconds. There
is no display for the "TR" models.

“Residual moisture” / “Time” / “Vented air”
display 

(Standard programming, see p. 19)

“Residual moisture” (%)
Display of the residual moisture set for pro-

grammes  

1

 to 

9

.

A few minutes after the programme has
started the residual moisture in the laundry is
recorded and displayed.

The current residual moisture values are
shown continuously during the programme.

“Time” (h/mins)

Display of the time set for programmes 

0

and 

!

.

The hours are shown in the left hand display
field and the minutes in the other two fields.
After the programme has started the remain-
ing time left to run is shown instead of the total
time.

“Vented air temperature” (

o

C)

Display of the current vented air temperature
while a programme is running. Display lasts
for approx 5 seconds. There is no display for
the "TR" models.

Note:

After the start button has been pressed a turn-
ing circle is shown for a short time in the dis-
play (meant to represent the turning drum of
the dryer).

Indicator lights “Residual moisture” /
“Time left”

“Residual moisture”
Lights up when the machine is switched on

and programme 

1

 or 

9

 is chosen.

It goes out at the end of the programme.

“Time left”
Lights up when the machine is switched on

and a programme between 

0

and 

!

 is chosen.

It goes out at the end of the programme.

Selector button

Display

Indicator lights

9

«M.-Nr.04989220/02 - GB - »

Summary of Contents for T 6251

Page 1: ...ons Tumble Dryers T 6251 T 6351 T 6551 T 6751 T 6551 TR It is essential to read these operating instructions before installing Q or using the machine to avoid the risk of accident or damage to the machine M Nr 04989220 02 ...

Page 2: ... These instructions consist of 26 pages Diese Gebrauchsanweisung besteht aus 26 Seiten 2 M Nr 04989220 02 GB ...

Page 3: ...f washing 12 Weights of load 12 Programme selection 13 Coin operation unit 14 Notes 15 Anti crease 15 Interrupting a programme 15 Emergency Stop switching off 15 Altering a drying programme examples 16 Reprogramming possibilities Programmable residual moisture 19 Cleaning and care 20 Meaning of the symbols on the data plate 21 Notes for the installer 22 Adjustable feet 23 Electrical connection 23 ...

Page 4: ...g Repairs to machines operated by gas steam or electricity must only be carried out by fully trained and qualified service engi neers Unauthorized repairs could be danger ous The electrical safety of this appliance can only be guaranteed when continuity is com plete between the appliance and an effective earthing system which complies with local and national regulations It is most important that t...

Page 5: ...ons to take if you smell gas For gas heated dryers only Natural gas usually has no smell of its own In the U K a smell is added by British Gas for safey reasons If you smell gas you must act immediately Extinguish any flames Do not create any electrical sparks e g do not insert or withdraw any electrical plugs or operate electrical switches such as lights and door bells Do not enter a room with an...

Page 6: ...ather than just throwing these materials away please ensure they are offered for recy cling Disposal of your old machine Old machines contain materials which can be re cycled Please contact your local authori ties or scrap merchant about potential recy cling schemes before disposing of the appliance Ensure that the machine presents no danger to children while being stored for disposal 6 M Nr 04989...

Page 7: ...table screw feet 4 Door handle 8 Venting pipework Venting socket Control panel 9 Re set button 11 Programme selector only for tumble dryers with gas heating 12 Push button switches 10 Indicator lights 13 Additional display with selector button Programme sequence and check 14 Emergency Stop switch lights 1 2 3 4 8 5 6 7 9 10 11 12 13 14 7 M Nr 04989220 02 GB ...

Page 8: ... the programme when pushed in Programme selector The programme selector switch is used to se lect the programme required ACOTTONS Residual moisture value T6251 6351 T6551 6751 1Extra dry 4 4 2Normal 2 2 3Normal 3 3 4 Machine iron r 13 16 5 Machine iron rr 20 22 6 Machine iron rrr 26 30 BMINIMUM IRON 7Normal 2 2 8Normal 2 2 9 Machine iron r 8 8 C TIMED DRYING 0 without heating 15 min 15 min with he...

Page 9: ...for pro grammes 1 to 9 A few minutes after the programme has started the residual moisture in the laundry is recorded and displayed The current residual moisture values are shown continuously during the programme Time h mins Display of the time set for programmes 0 and The hours are shown in the left hand display field and the minutes in the other two fields After the programme has started the rem...

Page 10: ...there is a power cut or if a programme has been interrupted e g when a door has been opened and shut They are not indicative of a fault The lights will stop flashing when the Start button is pressed This only applies to gas heated machines Gas The gas check light comes on when The site gas supply to the machine is inter rupted e g gas stop valve has not been opened Action Open the gas stop valve T...

Page 11: ...cates an ignition fault Wait for at least one minute before push ing the button to re set Emergency Stop switch Only use in an emergency Do not use this switch in normal operation to switch the machine off To reset the emergency stop switch after it has been used turn the ribbed disk clockwise 11 M Nr 04989220 02 GB ...

Page 12: ...ed with the zips open Padded or filled fabrics eg jackets or cush ions should not be dried If the filling falls out it could cause a fire Some woven and loopknit materials tend to shrink to varying extents depending on their quality This tendency is exaggerated by over drying Avoid the Extra dry programme for such fabrics Starched washing can be dried in the tumble dryer Select the most suitable p...

Page 13: ...l 2 2 3Normal 3 3 4Machine Iron r 13 16 5Machine Iron rr 20 22 6Machine Iron rrr 26 30 BMINIMUM IRON For drying polyester cotton mixtures delicates and synthetics 7Normal 2 2 8Normal 2 2 9Hand Iron r 8 8 CTIMED DRYING Airing and timed drying 0without heating 15 mins For airing laundry with heating 20 mins To dry small loads or to finish off drying individual items If required also select the L Low...

Page 14: ...yer before the drying programme has finished ie the cooling down phase must be com pleted If hot laundry items are stacked or packed they can be liable to auto combustion If the laundry is rinsed with hot water in the final rinse the residual heat in the laundry together with the reduced residual moisture content will lead to shorter processing times and save energy The end of the drying programme...

Page 15: ...rogramme is interrupted either by opening the door opening the fluff filter panel 6 or operating the Emergency stop switch to start the machine again the Start button has to be pressed If a new programme is to be selected first turn the programme selector to End and then to the desired programme Press the Start button to start the new programme The On indicator light flashes if the pro gramme sele...

Page 16: ...he drum door closed All of the switches must also be in the Off po sition i e released not pressed in The programme selector must be at the r End position Press in the s On Off switch The On indicator light comes on Press the L low temperature button twice in and twice out within 4 seconds After a few seconds the letter P lights up in the left hand field of the additional display The programme seq...

Page 17: ... appears in the additional display Turn the programme selector to the r End position The change to the drum reversing action pe riod in the cottons programmes is stored in memory The programming process is ended To leave the programming level Press the s On Off button Please enter the programming in the list on the next but one page Example 2 Changing the residual moisture value in pro gramme 5 to...

Page 18: ... is shown in the ad ditional display Press the h Start button repeatedly to select the required residual moisture of 18 Turn the programme selector to the r End position The change to the residual moisture value is stored in memory and the programming pro cess is ended To leave the programming level Release the s On Off switch Please enter the programming in the list on the following page See the ...

Page 19: ...g off Pause interval in Minimum iron programmes 7 to 9 B 7 3 seconds 0 Off or 2 to 10 seconds without heating Programme 10 8 15 minutes 3 minutes to 1 hour with heating followed by Cooling down Programme 11 9 20 minutes 3 mins 3 minutes to 3 hours add to this cooling down time to a cool temperature of 50 o C Standard value Timed drying Additional display during operation C 0 0 2 0 1 or 2 0 Residua...

Page 20: ...ts to clean the machine If you are unsure about a particular product or need further advice please contact your nearest Miele Sales office See back page for address The following should be checked and if neces sary cleaned once a year by a Customer Service Engineer Burner and burner cavity with gas heating heater element and heater shaft with electric heating The whole interior of the tumble dryer...

Page 21: ...13 Braking time 14 Heating 15 Electric heating 16 Fusing on site 17 Steam heating indirect 18 Steam heating direct 19 Gas heating 20 Commissioning date 21 Water Registration 22 Space for test certificate e g CE 0085 Gas or country certificate not valid for Tumble Dryers Noise emission Registered on the A scale T 6251 67 7 dB T 6351 72 7 dB T 6551 74 2 dB T 6751 75 1 dB measured in Germany in accor...

Page 22: ...nds as short a duct as possible well shaped and leakproof joints No filters or louvres should be built into the ex haust duct The connection between the exhaust ducting and the exhaust connection on the dryer must be airtight Where the exhaust is ducted directly into the open air the end of the duct should be pro tected against the weather ideally by a down ward angle of 90o To facilitate subseque...

Page 23: ...tions Connection must be made by a suitable isola tor and the on off switch should be easily accessible for servicing work WARNING THIS APPLIANCE MUST BE EARTHED Follow instructions given on the enclosed wir ing diagram with the machine on the terminal block These are important for the correct electrical connection to be made WARNING Ensure that the ventilation motor is turning in the correct dire...

Page 24: ... nance of heating and ventilation systems with particular regard to the use of heat ex changers Gas connection The gas connection may only be carried out by a suitably qualified e g Corgi registered engineer in accordance with local and na tional safety regulations The enclosed instal lation diagram and the installation instructions for gas must be followed to ensure correct gas connection Please ...

Page 25: ...Notes 25 M Nr 04989220 02 GB ...

Page 26: ... Oxon OX14 1TW Tel Abingdon 01235 554455 Fax 01235 554477 Service Office tel Abingdon 01235 554466 Telephone calls may be monitored and recorded to improve our service Alteration rights reserved 12 03 This paper is made from 100 chlorine free bleached cellulose ...

Reviews: