en - Technical data
41
Voltage versions and electrical data
3N AC 400 V EL
Supply voltage
3N AC 400 V
Frequency
50/60 Hz
Required fuse rating (on site)
35 A
Power rating
19 kW
Connection cable, min. cross-section
6 mm²
3N AC 400 V RH
Supply voltage
3N AC 400 V
Frequency
50/60 Hz
Required fuse rating (on site)
16 A
Power rating
10 kW
Connection cable, min. cross-section
2,5 mm²
3 AC 230 V EL
Supply voltage
3N AC 230 V
Frequency
50/60 Hz
Required fuse rating (on site)
50 A
Power rating
19 kW
Connection cable, min. cross-section
10 mm²
3 AC 440/480 V EL
Supply voltage
3 AC 440/480 V
Frequency
50/60 Hz
Required fuse rating (on site)
35 A
Power rating
19,5/22,5 kW
Connection cable, min. cross-section
6 mm²
3 AC 400 V EL
Supply voltage
3 AC 400 V
Frequency
50/60 Hz
Required fuse rating (on site)
35 A
Power rating
19 kW
Connection cable, min. cross-section
6 mm²
Summary of Contents for PWM 920 EL
Page 2: ...2 de 4 en 25 fr 45 es 67 ru 88 it 110 ...
Page 18: ...de Aufstellung INSTALLATION 18 Standard Maßangaben in Millimeter Standfuß ...
Page 19: ...de Aufstellung INSTALLATION 19 Sockel Maßangaben in Millimeter ...
Page 38: ...en Installation INSTALLATION 38 Standard Dimensions in mm Machine foot ...
Page 39: ...en Installation INSTALLATION 39 Plinth Dimensions in mm ...
Page 59: ...fr Installation INSTALLATION 59 Par défaut Dimensions en millimètres Pied ...
Page 60: ...fr Installation INSTALLATION 60 Socle Dimensions en millimètres ...
Page 81: ...es Emplazamiento INSTALLATION 81 Estándar Medidas en milímetros Base de apoyo ...
Page 82: ...es Emplazamiento INSTALLATION 82 Zócalo Medidas en milímetros ...
Page 103: ...ru Установка INSTALLATION 103 Стандарт Размеры в мм Ножка ...
Page 104: ...ru Установка INSTALLATION 104 Цоколь Размеры в мм ...
Page 124: ...it Posizionamento INSTALLATION 124 Standard Misure in millimetri Piedino ...
Page 125: ...it Posizionamento INSTALLATION 125 Base Misure in millimetri ...