Dispenser system connections
Connections
1
and
2
are for viscous agents
only. These connections are sealed and
have to be drilled open with an 8 mm drill
bit.
Electrical connection
The electrical connection must only be
carried out by a suitably qualified electrician
in accordance with local and national safety
regulations (BS 7671 in the UK).
When installing a residual current device
(RCD), this must be a Type B RCD (suitable
to detect high frequency AC and DC earth
leakage current).
Connection should be made in accordance
with the wiring diagram and the installation
diagram to a suitable isolator, with an on-off
switch which is easily accessible for
servicing. The wiring and installation
diagrams are important for the correct
electrical functioning of the machine.
The electrical components on the PW 6163,
PW 6243 and PW 6323 machines conform to
EN 60204.
The connection points are located behind a
cover. The mains cable should be fed
through the core to the connection clamps.
The machine is supplied ex-works for 3N AC
50-60 Hz. See data plate for details.
It is also available in the following
versions:
3 N AC 380-415 V 50-60 Hz
3 AC 220-240 V 50-60 Hz
Notes for the installer
Only
drill
through
the
first
wall.
A
second
one
is
located
10
mm
behind
it
to
deflect
the
agent.
Any
connections
that
have
been
drilled
open
must
be
resealed
if
they
are
subsequently
not
required.
Connections
3
to
12
are
for
liquid
agents
only.
These
connections
are
also
sealed
and
have
to
trimmed
to
the
correct
diameter
for
the
hoses
being
used
with
a
suitable
small
saw.
Any
connections
that
have
been
opened
must
be
resealed
if
they
are
subsequently
not
required.
43