Miele PW 6055 AV Installations Plan Download Page 2

 
 

 

10 145 220 / 01 

 

Legend: 

 

Connection required 

 

Connection optional or required for 
a specific model 

AV 

Drain valve 

KW 

Cold water connection 

AW 

Waste water connection 

LP 

Soap water pump 

Appliance fastening 

PA 

Equipotential bonding 

BW 

Service water connection 

SLA 

Peak load connection 

DOS  Dosing unit connection 

UG 

Base, closed 

EL 

Electrical connection 

UO 

Base, open 

Adjustable appliance mounts 

WTV  Washer/dryer connection 

KG 

Payment device 

WW 

Hot water connection 

KGA  Payment device connection 

XKM  Communication module 

 

 
 

Alteration rights reserved 08/14/155 

Summary of Contents for PW 6055 AV

Page 1: ...ion Plan Washing Machine PW 6055 AV LP PW 6065 AV LP Read all operation and installation instructions prior to assembly installation and initial operation to prevent injury and machine damage en US 10 145 220 01 ...

Page 2: ... pump B Appliance fastening PA Equipotential bonding BW Service water connection SLA Peak load connection DOS Dosing unit connection UG Base closed EL Electrical connection UO Base open F Adjustable appliance mounts WTV Washer dryer connection KG Payment device WW Hot water connection KGA Payment device connection XKM Communication module Alteration rights reserved 08 14 155 ...

Page 3: ...PW 6055 6065 en 10 145 220 01 3 Appliance Dimensions PW 6055 ...

Page 4: ...en PW 6055 6065 4 10 145 220 01 Installation PW 6055 ...

Page 5: ...PW 6055 6065 en 10 145 220 01 5 Washer Dryer Stack PW 6055 ...

Page 6: ...en PW 6055 6065 6 10 145 220 01 Appliance Dimensions PW 6065 ...

Page 7: ...PW 6055 6065 en 10 145 220 01 7 Installation PW 6065 ...

Page 8: ...en PW 6055 6065 8 10 145 220 01 Washer Dryer Stack PW 6065 ...

Page 9: ...PW 6055 6065 en 10 145 220 01 9 Assembly ...

Page 10: ...en PW 6055 6065 10 10 145 220 01 Assembly ...

Page 11: ...consumption 60 C standard program 36 l h 36 l h 40 l h 40 l h User supplied connection with external thread as per DIN 44991 flat sealing Connection hose with screw fitting Connecting hose length 5 1 1550 mm 5 1 1550 mm 5 1 1550 mm 5 1 1550 mm Hot water WW Max inlet temperature 158 F 70 C 158 F 70 C 158 F 70 C 158 F 70 C Permissible water flow pressure 100 1000 kPa 100 1000 kPa 100 1000 kPa 100 10...

Page 12: ...l diameter x length 5 16 x 1 9 16 8 x 40 mm 5 16 x 1 9 16 8 x 40 mm 5 16 x 1 9 16 8 x 40 mm 5 16 x 1 9 16 8 x 40 mm Floor mounting Miele base Accessories for Miele base fasteners supplied with product Required fastening points Number 4 4 4 4 Wood screw as per DIN 571 5 16 x 2 9 16 8 x 65 mm 5 16 x 2 9 16 8 x 65 mm 5 16 x 2 9 16 8 x 65 mm 5 16 x 2 9 16 8 x 65 mm Dowel diameter x length x 2 3 8 12 x...

Page 13: ... UG 5005 Base galvanized stainless steel side panels Base closed H 1 6 470 mm UG 5005 47 Base galvanized octoblue heat cure coated side panels Base closed H 2 5 750 mm UG 5005 75 Base galvanized octoblue heat cure coated side panels Base open UO Base open H 11 13 16 300 mm UO 5005 Base galvanized octoblue heat cure coated surface Base open H 1 6 470 mm UO 5005 Base galvanized octoblue heat cure co...

Page 14: ...e such as timers must not be installed The conductor cross section information in the technical data refers only to the required connecting cable Refer to the applicable national and local regulations for calculating the other dimensions Cold water connection You may connect the washing machine to a drinking water system without a backflow preventer because it has been designed according to the ap...

Page 15: ...ce for this function Alternatively you can use a wireless multi station system for maximum 8 terminals with a debit card payment device and additional controllers for terminal monitoring Serial interface The serial interface is provided with an additional integrated XKM RS323 module The data interface leading from the XKM RS232 module is compliant with SELV safety extra low voltage Any connected e...

Reviews: