Equipotential
bonding
Connection with male thread
3/8“ x 1 3/8“
10 × 35 mm
with washers and nut.
10 M
Accessories not included (except with offshore version).
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Vented
Max. nominal air flow in vented mode
470cfm
800 m³/h
Max. permissible pressure loss
0.04 psi
300 Pa
Connection on machine side (ext. diameter)
5 15/16“
150 mm
Connection pipe provided on site (int. diameter)
5 15/16“
150 mm
Max. temperature
176°F
80°C
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection:
Air intake from installation site
Unobstructed air intake into room recommended (corre-
sponding to 3 times the vent cross-section of machine)
83 in²
531 cm²
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Alternative connection:
Ducted air intake (from outside
building)
Connector on machine (int. diameter)
6 5/16“
161 mm
Connection pipe provided on site (ext. diameter)
6 5/16“
160 mm
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm (35 ½”) long and secured using two screws.
Fittings
(supplied)
Without base
2 × clamps
2 × screws DIN 571 (Ø × length)
¼ x 1 9/16“
6 x 40 mm
2 × rawl plugs (Ø × length)
3/8 x 2“
10 x 50 mm
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
On concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
¼ x 1 9/16“
6 × 40 mm
2 × rawl plugs (Ø × length)
3/8 x 2“
10 × 50 mm
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Unit width
35 11/16“
906 mm
Machine depth
45 13/16“
1164 mm
Unit height
55 1/8“
1400 mm
Casing width
35 7/16“
900 mm
Casing depth
41 11/16“
1059 mm
Minimum width of delivery access to installation site
36 ¼“
920 mm
Recommended rear wall gap (measured to front of machine)
63“
1600 mm
Min. wall gap (to rear edge of lid)
19 11/16“
500 mm
Net weight
422 lb
191 kg
Dynamic floor load, max.
2170 N
2170 N
Average heat dissipation
(dependent on ambient room temperature and program
selected)
2220 BTU/hr
0.65kW
Noise level
72.8 dB (A)
72.8 dB (A)
Sound pressure level
(measured at a distance of 1 m from the machine and at a
height of 1.6 m)
60 dB (A)
60 dB (A)
Installation should only be carried out by authorized fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved!
Installation plan: PT 8407 EL (Electric)
Date: 01.2015
Page: 12
Summary of Contents for PT 8407 EL
Page 2: ...M Nr 10 166 230 00 2 ...
Page 3: ...PT 8407 EL Electric Électrique PT 8407 EL measurements in inches mesures en pouces 3 ...
Page 4: ...PT 8407 EL Electric Électrique 4 ...
Page 5: ...PT 8407 EL Electric Électrique 5 ...
Page 8: ...PT 8407 EL Electric Électrique 8 ...