Miele PT 8407 EL Installations Plan Download Page 12

 

 

 

Equipotential 

bonding 

Connection with male thread  

3/8“ x 1 3/8“ 

10 × 35 mm 

with washers and nut.  

 

10 M 

Accessories not included (except with offshore version). 

 

 

If necessary, equipotential bonding with good galvanic 
contact must be provided in accordance with all appropriate 
national and local regulations. 

 

 

 

Vented 

Max. nominal air flow in vented mode  

470cfm 

800 m³/h 

Max. permissible pressure loss 

0.04 psi 

300 Pa 

Connection on machine side (ext. diameter) 

5 15/16“ 

150 mm 

 

Connection pipe provided on site (int. diameter) 

5 15/16“ 

150 mm 

 

 

Max. temperature 

176°F 

80°C 

 

 

As relative humidity inside the vent ducting can be as high as 
100%, suitable measures must be taken to prevent a 
backflow of condensate into the machine. 

 

 

 

 
 

Air intake 

Standard connection:

 Air intake from installation site 

 

 

Unobstructed air intake into room recommended (corre-
sponding to 3 times the vent cross-section of machine) 

 83 in² 

531 cm² 

A sufficient supply of fresh air should be ensured to 
replace the air extracted. 

 

 

Alternative connection:

 Ducted air intake (from outside 

building) 

 

 

 

 

Connector on machine (int. diameter) 

6 5/16“ 

161 mm 

 

 

Connection pipe provided on site (ext. diameter) 

6 5/16“ 

160 mm 

 

 

Lid removal exposes live components! For safety reasons, 
the pipe connected for central air intake should be at least 
900 mm (35 ½”) long and secured using two screws. 

 

 

 

 

 

Fittings 

(supplied) 

 

Without base 

 

 

2 × clamps 

 

 

2 × screws DIN 571 (Ø × length) 

¼  x 1 9/16“ 

6 x 40 mm 

 

2 × rawl plugs (Ø × length) 

3/8 x 2“ 

10 x 50 mm 

 

 

The machine should be bolted to the floor. 

 

 

 

 

Fixing materials for a floating screed floor are to be provided 
on site. 

 

 

 

 

On concrete base 

 

 

 

 

2 × clamps 

 

 

 

 

2 × screws DIN 571 (Ø × length) 

¼ x 1 9/16“ 

6 × 40 mm 

 

 

2 × rawl plugs (Ø × length) 

3/8 x 2“ 

10 × 50 mm 

 

 

Machine must be bolted to the floor! 

 

 

 

 

Fixing materials for a floating screed floor are to be provided 
on site. 

 

 

 

Machine data 

Unit width 

35 11/16“ 

906 mm 

 

 

Machine depth 

45 13/16“ 

1164 mm 

 

 

Unit height 

55 1/8“ 

1400 mm 

 

 

Casing width 

35 7/16“ 

900 mm 

 

 

Casing depth 

41 11/16“ 

1059 mm 

 

 

Minimum width of delivery access to installation site 

36 ¼“ 

920 mm 

 

 

Recommended rear wall gap (measured to front of machine) 

63“ 

1600 mm 

 

 

Min. wall gap (to rear edge of lid) 

19 11/16“ 

500 mm 

 

 

Net weight  

422 lb 

191 kg 

 

 

Dynamic floor load, max. 

2170 N 

2170 N 

 

 

Average heat dissipation

 

(dependent on ambient room temperature and program 
selected) 

2220 BTU/hr 

0.65kW 

 

 

Noise level 

72.8 dB (A) 

72.8 dB (A) 

 

 

Sound pressure level

 

(measured at a distance of 1 m from the machine and at a 
height of 1.6 m) 

60 dB (A) 

60 dB (A) 

Installation should only be carried out by authorized fitters in accordance with valid regulations! 

 

Observe installation instructions when installing machine! All rights reserved!  

 

Installation plan: PT 8407 EL (Electric) 

Date: 01.2015 

Page: 12 

 

Summary of Contents for PT 8407 EL

Page 1: ...Installation Plan Tumble dryer Plan d installation Sèche linge PT 8407 EL Electric PT 8407 EL Électrique en fr CA 05 15 M Nr 10 166 230 00 ...

Page 2: ...M Nr 10 166 230 00 2 ...

Page 3: ...PT 8407 EL Electric Électrique PT 8407 EL measurements in inches mesures en pouces 3 ...

Page 4: ...PT 8407 EL Electric Électrique 4 ...

Page 5: ...PT 8407 EL Electric Électrique 5 ...

Page 6: ...PT 8407 EL Electric Électrique Standard installation Installation standard Option Concrete platform Plateforme en bèton 6 ...

Page 7: ...PT 8407 EL Electric Électrique PT 8407 EL measurements in millimeters mesures en millimètres 7 ...

Page 8: ...PT 8407 EL Electric Électrique 8 ...

Page 9: ...PT 8407 EL Electric Électrique 9 ...

Page 10: ...PT 8407 EL Electric Électrique Standard installation Installation standard Option Concrete platform Plateforme en bèton 10 ...

Page 11: ... x 65 Connection cable supplied without power cord Cable screw connector M 40 Electrical connection must comply with national regulations Connection using multi pole lockable wall socket in compliance with IEC EN 60309 and IEC EN 60947 is recommended in order to simplify electrical tests If machines are hard wired a multi pole mains switch must be provided on site Switches with a contact gap of mo...

Page 12: ...ntral air intake should be at least 900 mm 35 long and secured using two screws Fittings supplied Without base 2 clamps 2 screws DIN 571 Ø length x 1 9 16 6 x 40 mm 2 rawl plugs Ø length 3 8 x 2 10 x 50 mm The machine should be bolted to the floor Fixing materials for a floating screed floor are to be provided on site On concrete base 2 clamps 2 screws DIN 571 Ø length x 1 9 16 6 40 mm 2 rawl plug...

Page 13: ...ni Le raccordement électrique doit être conforme aux règlements nationaux et locaux Il est conseillé de raccorder l appareil avec une prise avec sectionneurs omnipolaires et verrouillable conforme à IEC EN 60309 et IEC EN 60947 afin de pouvoir effectuer facilement les contrôles de sécurité électriques Si un raccordement fixe est prévu un dispositif de disjonction phase et neutre doit être présent ...

Page 14: ...ans laquelle fonctionnera la machine doit être aérée en fonction de la quantité d air évacuée Autre possibilité de raccordement Alimentation en air extérieur directe Manchon de raccordement côté machine diamètre intérieur 6 5 16 po 161 mm Tuyau de raccordement côté installation diamètre extérieur 6 5 16 po 160 mm Attention lorsque le couvercle de protection est déposé des composants sous tension s...

Page 15: ...max 2170 N 2170 N Dégagement de chaleur moyen dans la salle d installation dépend de la température ambiante et du programme choisi 2220 BTU h 0 65 kW Pression acoustique 72 8 dB A 72 8 dB A Niveau de pression acoustique au niveau du poste de travail distance 1 m et 1 6 m de hauteur 60 dB A 60 dB A L installation doit exclusivement être effectuée par des installateurs agréés conformément aux presc...

Reviews: