Technical datasheet
Tumble dryer:
Heating:
PT 8303 Slimline
Electric (EL)
Legend:
Abbreviations in bold type:
Connection required
en - CA
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Machine connections:
Electrical
connection
1. Standard voltage (as supplied)
3 AC 220 - 240 V
Frequency
60 Hz
Rated load
15.4 kW
Fuse rating
3 x 40 A
Supplied without power cord
2. Standard voltage ( convertible)
3 AC 208 V
Frequency
60 Hz
Rated load
11.7 kW
Fuse rating
3 x 35 A
Supplied without power cord
3. Standard voltage (convertible)
2 AC 208 V
Frequency
60 Hz
Rated load
8.1 kW
Fuse rating
2 x 40 A
Supplied without power cord
Electrical connection must comply with national regulations.
Connection using multi-pole lockable wall socket in
compliance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests. If machines
are hard-wired, a multi-pole mains switch must be provided
on site. Switches with a contact gap of more than 3 mm can
be used. These include switches, fuses and contactors
(IEC/EN 60947). A wall socket or mains isolator must be
easily accessible after installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a properly
trained electrician.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Vented
Nominal air throughput in vented mode
483 cfm
821 m³/h
Max. permissible pressure loss
0.0435 psi
300 Pa
Connection on machine side (int. diameter)
5 15/16“
150 mm
Connection pipe provided on site (ext. diameter)
5 15/16“
150 mm
Max. Temperature waste air/gas
176°F
80°C
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Installation plan: PT 8303
Date: Jan-2015
Page: 11
Summary of Contents for PT 8303 SL EL
Page 2: ...2 ...
Page 7: ...7 PT 8303 SL measurements in millimeters mesures en millimètres ...
Page 8: ...8 PT 8303 SL measurements in millimeters mesures en millimètres ...
Page 9: ...9 PT 8303 SL measurements in millimeters mesures en millimètres ...
Page 10: ...10 PT 8303 SL measurements in millimeters mesures en millimètres ...