Control panel PT 8251, 8331 Profitronic B COP (Coin Operation)
1
2
3
4
5
6
7
1
Segment display - Time
2
Programme sequence display
3
Temperature selection button
4
Venting system fault indicator
5
Fluff filter fault indicator
6
START/STOP button
7
On/Off switch
Time selection can be controlled by a
C 4065 coin control unit
or other type of payment system.
^
Press the mains On/Off switch
s
^
Load the drum and close the door.
Selecting a temperature
^
Press the temperature selection button and select
the required drying temperature -
Cold
,
Low
,
Medium
,
High
.
The corresponding LED will light up.
Cold
For
airing
fabrics
Low
Delicates
, synthetic fibre and rayon fabrics
Medium Minimum iron
, synthetic and mixed fibre
fabrics
High
Cottons
, cotton and linen fabrics
^
Insert coins or tokens.
The START/STOP button will start flashing.
^
Press the START/STOP button.
The temperature can only be altered in the first 3
minutes* after the programme has started.
*(can be changed in Service mode)
At the end of the drying duration
!
Drying
L
Cooling down
O
Programme finished / Anti-crease
At the end of the drying duration the "Drying" and
"Programme finished" programme sequence stage
symbols will flash. "Cooling down" will light up and the
cooling down phase will begin.
!
Drying
L
Cooling down
O
Programme finished / Anti-crease
At the end of the cooling down phase all three
programme stage symbols will flash and the buzzer
will sound.
^
Remove the laundry.
Interrupt the programme
by opening the drum door
or the fluff filter compartment flap:
^
Continue the programme by closing the drum
door/fluff filter compartment flap and pressing the
START/STOP button.
Short operating instructions which can be used as
a wall chart are supplied with the dryer.
PT 8251, 8331 COP
15
High
Medium
Low
Cold
Summary of Contents for PT 8251
Page 25: ...25 ...