Miele PT 8251 G Dimension Manual Download Page 10

 

Installationsplan / Installation plan: PT 8251/8253/8255/8257 
Datum / Date: 12.01.2011 

Seite / Page: 10 

 

 

 

Fittings (supplied)  Without plinth 

 

 

2 × clamps 

 

 

 

2 × screws DIN 571 (Ø × length) 

mm 

6 × 40 

 

 

2 × rawl plugs (Ø × length) 

mm 

10 × 50 

 

 

Machine must be bolted to the floor! 

 

 

 

 

Fixing materials for a floating screed floor are to be provided 
on site. 

 

 

 

 

On concrete platform 

 

 

 

 

2 × clamps 

 

 

 

 

2 × screws DIN 571 (Ø × length) 

mm 

6 × 40 

 

 

2 × rawl plugs (Ø × length) 

mm 

10 × 50 

 

 

Machine must be bolted to the floor! 

 

 

 

 

Fixing materials for a floating screed floor are to be provided 
on site. 

 

 

 

Machine data 

Unit width 

mm 

906 

 

 

Machine depth 

mm 

852 

 

 

Unit height 

mm 

1400 

 

 

Casing width 

mm 

900 

 

 

Casing depth 

mm 

747 

 

 

Minimum width of delivery access to installation site 

mm 

860 

 

 

Recommended rear wall gap (measured to front of machine) 

mm 

1300 

 

 

Min. wall gap (to rear edge of lid) 

mm 

500 

 

 

Net weight  

kg 

150 

 

 

Dynamic floor load, max. 

1624 

 

 

Average heat dissipation

 

(dependent on ambient room temperature and programme 
selected) 

512 

 

 

  A Noise level 

dB (A) 

68.6 

 

 

  A Sound pressure level

 

(measured at a distance of 1 m from the machine and at a 
height of 1.6 m)1 m 

dB (A) 

55 

Installation should only be carried out by authorised fitters in accordance with valid regulations! 

 

Observe installation instructions when installing machine! All rights reserved! Measurements in mm. 

 

Summary of Contents for PT 8251 G

Page 1: ...02 11 Mat NR 07 803 760 02 Installation plan Tumble dryers Installatieschema Droogautomaat PT 8251 G PT 8253 G PT 8255 G PT 8257 G nl NL en GB ...

Page 2: ...eert en in gebruik neemt Dat is veiliger voor uzelf en u voorkomt schade aan uw apparaat Technische wijzigingen voorbehouden It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...l connection 1 Standard voltage as supplied V 1N AC 220 240 Frequency Hz 50 Rated load kW 0 8 Fuse rating A 1 10 Connection cable min cross section mm 3 1 5 Cable screw connector M 20 Connection cable to be ordered separately Electrical connection must comply with national regulations Connection using multi pole wall socket in compliance with IEC EN 60309 and IEC EN 60947 is recommended in order t...

Page 9: ...nal air flow PT 8251 8253 8255 only m h 510 Max permissible pressure loss Pa 200 Connection on machine side ext diameter mm 150 Connection pipe provided on site int diameter mm 150 Max temperature C 80 This tumble dryer is a gas burning machine without a flow operated safety device with fan downstream of heat exchanger Technical design B22 as standard Waste gas pipework must be pressure tight Wast...

Page 10: ...nit width mm 906 Machine depth mm 852 Unit height mm 1400 Casing width mm 900 Casing depth mm 747 Minimum width of delivery access to installation site mm 860 Recommended rear wall gap measured to front of machine mm 1300 Min wall gap to rear edge of lid mm 500 Net weight kg 150 Dynamic floor load max N 1624 Average heat dissipation dependent on ambient room temperature and programme selected W 51...

Page 11: ...e aansluiting 1 Standaardspanning af fabriek V 1N AC 220 240 Frequentie Hz 50 Aansluitwaarde kW 0 8 Zekering A 1 10 Aansluitkabel draaddoorsnede minimaal mm 3 1 5 Kabelwartel M 20 De aansluitkabels worden niet bijgeleverd De elektrische aansluiting dient volgens de nationale en plaatselijke voorschriften te worden uitgevoerd Het is aan te bevelen het apparaat op een vergrendelbare contactdoos aan ...

Page 12: ...0 Aansluitbuis ter plaatse binnendiameter mm 150 Temperatuur max C 80 De droogautomaat geldt als gasstookplaats zonder stromingsbeveiliging met ventilator achter de warmtewisselaar Type B22 bijgeleverd De afvoerleiding voor de rookgassen dient dan ook drukdicht te zijn De rookgasaansluiting dient volgens de nationale en plaatselijke voorschriften te worden uitgevoerd Hiervoor moet afhankelijk van ...

Page 13: ...ns machine Breedte mm 906 Diepte mm 852 Hoogte mm 1 400 Breedte behuizing mm 900 Diepte behuizing mm 747 Breedte transportopening min binnenwerks mm 860 Aanbevolen afstand tot de wand tot voorkant apparaat mm 1 300 Minimale afstand tot de wand tot achterkant deksel mm 500 Nettogewicht kg 150 Vloerbelasting bij gebruik max N 1 624 Gemiddelde warmteafgifte aan de ruimte afhankelijk van omgevingstemp...

Reviews: