The Electrobrush switches itself off
but the indicator lamp remains green
The overheating protection mechanism
has been activated by the appliance
overheating or because of a blockage.
^
Switch the vacuum cleaner off, switch
off at the wall socket and remove the
plug.
The Electrobrush has to cool down. To
speed this up:
^
Reconnect the vacuum cleaner to the
Electrobrush and switch the vacuum
cleaner on.
^
Raise the suction tube and
connection socket to the vertical
position.
The Electrobrush will be ready for use
again after about ten minutes.
The light tube needs changing
See illustrations
h
and
i
Light tube specification:
– Fitting: G5
– Size: 16 x 212
– Wattage: 6 watts
– Shade: cool white
^
Switch the vacuum cleaner off, switch
off at the wall socket and remove the
plug.
^
Release the Electrobrush connection
socket.
^
Loosen the four fixing screws
underneath the Electrobrush
a
.
^
Take off cover
b
and roller connector
c
.
^
Unscrew the four fixing screws
d
which are now visible and separate
the base section
e
from the top
section
f
.
^
Replace the light tube.
^
Reassemble the Electrobrush by
reversing the procedure.
Maintenance and care
Removing threads and hairs
See illustration
j
^
Switch the vacuum cleaner off, switch
off at the wall socket and remove the
plug.
^
Cut any threads or hairs that have
become entangled in the roller with a
pair of scissors.
There is a groove along the roller to
help you. Then run the vacuum cleaner
to vacuum up the bits.
G