All electrical work must be
carried out by a suitably qualified
and competent person, in
accordance with current local and
national safety regulations (BS 7671
in the UK).
– Ensure power is not supplied to this
machine until after it has been
installed.
– We recommend that connection to
the power supply be made via a
suitable plug and socket which must
be accessible for service and
maintenance work after the machine
has been installed.
– For hard-wired machines, connection
should be made via a suitable mains
switch with all-pole isolation which
when in the off position ensures a
3 mm gap between all open
contacts.
– An electrical safety test must be
carried out after installation and after
any service work.
– Equipotential bonding should be
carried out if required.
– The mains connection cable may
only be replaced by an original Miele
spare part or an apppropriate cable
with
wire end ferrule
.
– For technical data see data plate or
wiring diagram supplied.
The machine must only be operated
with the voltage, frequency and fusing
shown on the
data plate
.
This machine
can be converted to a
different type of power supply
in
accordance with the
conversion
diagram
and
wiring diagram
supplied.
Converting the machine to a
different type of power supply can
lead to longer programme durations
resulting in increased energy
consumption.
The values declared on the label will
only be achieved if the machine
remains in the state it was delivered
in.
Data plates
showing relevant test
marks are located at the back of the
dishwasher and inside the door.
The
wiring diagram
is supplied with
the machine.
The
conversion chart
is secured
behind the plastic plinth panel.
WARNING
THIS MACHINE MUST BE EARTHED
Electrical connection
63
Summary of Contents for PG 8081i
Page 77: ...77 ...
Page 78: ...78 ...
Page 79: ...79 ...