Installation PG 8059
08.12.2015
6
4. Voltage (standard version)
V/Hz AC
208/60
Connected load
kW
5.8
Fuse rating
A
2 x 30
Connection cable, min. gauge
mm²
3 x AWG10
Length of connection cable (UL 921) with plug
m
Approx. 1.9
Voltage
Convertible
V/Hz
3 AC 208/60
Connected load
kW
5.8
Fuse rating
A
3 x 20
Connection cable, min. gauge
mm²
4 x AW12
Length of connection cable (UL 921) with plug
m
Approx. 1.9
5. Voltage (standard version)
V/Hz AC
240/60
Connected load
kW
5.8
Fuse rating
A
2 x 30
Connection cable, min. gauge
mm²
3 x AWG10
Length of connection cable (UL 921) with plug
m
Approx. 1.9
Voltage
Convertible
V/Hz
3 AC 240/60
Connected load
kW
5.8
Fuse rating
A
3 x 20
Connection cable, min. gauge
mm²
4 x AW12
Length of connection cable (UL 921) with plug
m
Approx. 1.9
It is always recommended to make electrical connection via a
plug and socket so that electrical safety checks, e.g. during
repair or service work, can be carried out easily. The socket
must be accessible after machine installation. A fixed
electrical connection is possible via an on-site main switch
providing complete isolation from the mains for all poles. The
contact gap must be at least 3 mm. In order to increase
safety, the installation of an earth leakage circuit breaker is
recommended. If necessary, equipotential bonding with good
galvanic contact must be guaranteed in compliance with all
applicable local and national installation codes.
Protection class IP 21
Cold water
Two cold water connections are required for models with a
steam condenser (DK). The second cold water hose can be
connected using the Y-piece provided.
Maximum temperature
°C
20
Max. water hardness
°dH
60
Minimum flow pressure
kPa
200
Minimum flow pressure with extended water intake
kPa
100
Maximum pressure
kPa
1000
Flow rate
l/min
7.5
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Inch
3/4" male thread
(USA: 11.5 NH)
Length of connection hose (included) m
Approx.
1.7
Connection hose length - Steam condenser m
Approx.
1.7
Connection to a drinking water supply is permissible without
an additional non-return device.
Hot water
Maximum temperature
°C
65
Max. water hardness
°dH
60
Minimum flow pressure
kPa
200
Minimum flow pressure with extended water intake
kPa
40
Maximum pressure
kPa
1000
Flow rate
l/min
7.5
On-site threaded union in accordance with DIN 44991 (flat
sealing)On-site threaded union in accordance with DIN 44991
(flat sealing)
Inch
3/4" male thread
(USA: 11.5 NH)
Length of connection hose (included) m
Approx.
1.7
Connection to a drinking water supply is permissible without
an additional non-return device.
Waste water
Drain hoses (int. dia. x wall thickness)
mm
22 x 6
Length of drain hose - Machine
m
Approx. 1.5
Max. drain hose extension
m
Approx. 4.0
Max. drain pump head height from base of machine
m
1.0
Max. transient flow rate
l/min
16
On-site hose sleeve for drain hose (dia. x length)
mm
22 x 30