To convert the burners
Turn off the main gas supply (if the
appliance has already been
installed) and disconnect the
appliance from the main electrical
power supply before proceeding.
The following jets and needle valves
should be installed into their respective
burners. Follow codes accordingly.
Conversion table KM 342
Code
Jet size
(Ø mm)
Code
Needle
valve
size
(Ø mm)
Natural gas
Normal
burner
140
1.40
62
0.62
Fast burner
167
1.67
78
0.78
Wok burner
inner
outer
34
190
No. 34
1.90
40
88
0.40
0.88
Propane (LP)
Normal
burner
90
0.90
41
0.41
Fast burner
103
1.03
45
0.45
Wok burner
inner
outer
7
109
No. 7
1.09
25
54
0.25
0.54
Conversion table KM 344
Code
Jet
size
(Ø
mm)
Code
Needle
valve
size
(Ø mm)
Natural gas
Normal
burner
140
1.40
62
0.62
Fast burner
167
1.67
78
0.78
Wok burner
left
inner
outer
34
190
No. 34
1.90
40
88
0.40
0.88
Wok burner
right
inner
outer
34
195
No. 34
1.95
40
88
0.40
0.88
Propane (LP)
Normal
burner
90
0.90
41
0.41
Fast burner
103
1.03
45
0.45
Wok burner
left
inner
outer
7
109
No. 7
1.09
25
54
0.25
0.54
Wok burner
right
inner
outer
7
112
No. 7
1.12
25
54
0.25
0.54
Converting KM 342 / 344