![Miele KFN 14842 SD ed Operating And Installation Manual Download Page 44](http://html.mh-extra.com/html/miele/kfn-14842-sd-ed/kfn-14842-sd-ed_operating-and-installation-manual_235530044.webp)
. . . "
dn
" appears in the temperature
display.
The demonstration function is activated.
^
Call the Service Department.
. . . you cannot switch the appliance
off.
The safety lock has been activated.
. . . the interior lighting in the
refrigerator section is not working.
^
Was the door left open for too long?
The lighting switches itself off
automatically after approx. 15
minutes if the door is left open.
If this is not the case, then the interior
lighting is defective.
^
Disconnect the appliance from the
mains. Switch off at the wall and
withdraw the plug from the socket, or
disconnect the mains fuse or remove
the screw-out fuse in countries where
this is applicable.
^
Unclip the front cover.
^
Remove the glass panel.
^
Unscrew lamp and replace with a
new one.
Lamp specification:
220 - 240 V, max. 25 W, E 14 fitting.
^
Slide the glass panel back in again.
^
Insert the cover and clip it into
position.
. . . the floor of the refrigerator is wet.
The condensate drain hole is blocked.
^
Clean the condensate channel and
drain hole.
If you still cannot remedy the fault
having followed these suggestions,
please contact the Miele Service
Department.
To prevent unnecessary loss of
temperature it is advisable not to
open the doors while waiting for the
appliance to be serviced.
Problem solving guide
44