background image

Fully Integrated 36” Bottom Mount

KF 1913 Vi / KF 1903 Vi

KF 1913 Vi / KF 1903 Vi

Page 4 of 7

CUSTOM PANEL INSTALLATIONS

Panel 

"B" 

Heigh

t

Width:

35 3/4" in all cases

Thickness:

Minumum 3/4" outside frame

Standard Upper Panel Height:

  53 5/16"

Notes

: Finish back side of panels to insure appearance

Panel may extend above unit. This is 

not

considered in height calculation

Upper Maximum panel weight

:

83.8 Pounds

Lower Panel Height:

 Use the following calculation:

Panel Height 

= HOM - 53 9/16 - TKH

HOM

 = Total height of machine. Can be adjusted to

match adjoining cabinets - 

typically 84"

HOM is adjustable between 83 1/2" - 85 3/8"

TKH

 = Toe-kick height (2" - 8 3/8")

Lower Maximum panel weight

:

31 Pounds

Upper Panel

TKH

HO

M

Panel 

Height

These units do not come equipped with a front panel

. They are designed to accept a custom door panel supplied by

the cabinet maker.  Miele has a unique panel integration system which allows the panels to align with the surrounding
cabinets.

Panel size is determined in the following manner:

Lower Panel

Upper Panel Notes

If the adjoining cabinets are taller than the height of machine (HOM) - the upper panel may be extended accordingly.
Find the difference between height of the adjoining cabinets and the height of machine (HOM) and add to 53 5/16"

Adjoining cabinet

Machine

Extended Panel

Example:

Ajoining cabinet height:

87"

Height of machine:

84"

Difference:

3"

Extended panel height:

56 5/16"

Summary of Contents for KF1913 Vi

Page 1: ...Fully Integrated 36 Bottom Mount KF 1913 Vi KF 1903 Vi 8mieleusa com ...

Page 2: ... rear Standard NEMA 5 15 Duplex Outlet locate less than 9 above finished floor 1 4 flexible water line tape to floor E O W All Installations must be done in accordance with local codes Sides of adjoining cabinets should be filled flush to frame to insure proper fit and finish Location Codes UNIT ACCEPTS TWO 2 CUSTOM FRONT PANELS 8 3 8 2 O W For Proud Installation please adjust accordingly Depth as...

Page 3: ...Fully Integrated 36 Bottom Mount KF 1913 Vi KF 1903 Vi KF 1913 Vi KF 1903 Vi Page 3 of 7 LOWER HINGE LOCATION Upper Door 29 11 16 29 1 8 29 1 2 Hinge Hinge Lower Drawer 1 2 2 3 8 FRONT VIEW ...

Page 4: ... 1 2 85 3 8 TKH Toe kick height 2 8 3 8 Lower Maximum panel weight 31 Pounds Upper Panel TKH HOM Panel Height These units do not come equipped with a front panel They are designed to accept a custom door panel supplied by the cabinet maker Miele has a unique panel integration system which allows the panels to align with the surrounding cabinets Panel size is determined in the following manner Lowe...

Page 5: ...3 4 1 1 1 4 1 1 2 0 1 8 F r o n t P a n e l 0 3 4 1 1 4 1 1 2 1 3 4 1 Cabinet Front r o o D 5 1 1 r o o D 0 9 s n o i t p o s s e n k c i h T s n o i t p o s s e n k c i h T Door Swing NOTE Additional space needed depending on thickness of front panels and handle used 38 11 16 7 16 Door Swing 16 7 8 MAX NOTE Additional space needed depending on thickness of front panels and handle used ...

Page 6: ... Page 6 of 7 HINGING DETAILS 0 3 4 1 1 1 4 1 1 2 0 1 8 F r o n t P a n e l 0 3 4 1 1 4 1 1 2 1 3 4 1 Cabinet Front r o o D 5 1 1 s n o i t p o s s e n k c i h T Door Swing 16 7 8 MAX 3 76 2mm 13 4 44 5mm 13 8 35mm 11 6 29 6mm 1 4 6 4mm 17 24 18mm 21 24 52mm 21 3 59mm 25 8 67mm ...

Page 7: ...o s s e n k c i h T s n o i t p o s s e n k c i h T Door Swing 38 11 16 7 16 Door Swi 16 7 8 MAX 7 16 11 mm 13 16 30mm 17 16 36 5mm 111 16 43mm 115 16 49 2mm Handle or object that is NOT flush with Cabinet Front When installing hing side next to an appliance or object that is within range of the door panel limit the door opening angle to 90O This is done by installing the banking pin as illustrate...