This appliance must be built in,
otherwise it could tip up.
Location
This appliance should not be installed
where it is exposed to direct sunlight or
directly adjacent to a heat-producing
appliance such as an oven or a
radiator. The higher the ambient
temperature of the room, the more
energy the appliance requires to
operate. The appliance should be
installed in a dry well ventilated room.
When installing the appliance please
be aware:
– The socket must be easily accessible
in an emergency, not concealed
behind the appliance.
– The plug and cable must not touch
the rear of the appliance as they
could be damaged by vibrations
from the appliance.
– Do not plug in other appliances
behind this appliance.
Important. In environments with
high humidity
condensation can
build up on the exterior of the
appliance. This can cause corrosion
of the appliance walls.
For prevention, it is advisable to
install the appliance with sufficient
ventilation in a dry and /or
air-conditioned room.
Make sure that the appliance door(s)
closes properly, the ventilation gaps
are not covered and the appliance is
installed in accordance with these
installation instructions.
Climate range
The appliance is designed for use
within certain climate ranges (ambient
temperatures) and should not be used
outside this range. The climate range of
the appliance is stated on the data
plate inside the appliance.
Climate range
Ambient room
temperature
SN
N
ST
T
+10 °C to +32 °C
+16 °C to +32 °C
+16 °C to +38 °C
+16 °C to +43 °C
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the internal
temperature in the appliance to rise
with the risk of food deteriorating and
going off.
Installation
49