background image

 
 

Technical Information 

 

 

K 18x1/19x1

 

2 Service 

Programming 

1.  Turn on the appliance.  
2.  Touch the thermometer  .  
3.  Touch the refrigerator icon   to access the refrigerator.  
4.  Note the position of the down arrow

. (If the current temperature setting 

is at the minimal setting of 36°F, then this icon will not be lit. Touch the up 
arrow 

 to raise the temperature and to make the down arrow visible.) 

5.  Touch the thermometer   to turn off the display. 
6.  Press and hold in the area of the down arrow

7.  Touch the thermometer   once. 
8.  Release the down arrow

, then touch it again 5 times; hold on the 5th  

  

time 

until 

P

 is displayed. 

9.  Scroll through, using the arrows, to the desired function (e.g., 

A

). See 

Table 2 for a list of functions. Touch the thermometer   to access   the 
options for that function. For example, if 

A

 was selected, 

A – 

will be 

displayed after the thermometer is touched. 

10. Scroll through to the desired option. If an option is flashing, then it can be 

selected. If it is lit steadily, then it has been programmed. See Table 2 for 
a list of options for each function. 

11. Touch the thermometer   to save the option. It will now be steadily lit.  
12. Scroll through to 

– 

(e.g., 

A –

).  

13. Touch the thermometer   to exit to the list of functions. 

A

 (as an example) 

 

 

will now be displayed. Scroll to other functions to make changes, or scroll  

  

back 

to 

P

 and then touch the thermometer   to quit.  

14. To quit without saving any changes, close the appliance door or do not  

 

 

touch any icons for 2 minutes. 

Service Programming Settings 

Symbol Function 

Options 

Factory 

Setting

Main menu 

--- 

--- 

Restoring factory 
settings 

A0:

 Factory settings have not 

been changed 

A0 

A1:

 Settings have been changed 

I- 

Temperature format 

l-0:

 °F 

°F (I-0) 

l-1:

 °C 

RemoteVision 
module programming

r0:

 Log off 

--- 

r1:

 Log on

r2:

 Reset RemoteVision module

 

r3:

 Reset RemoteVision module and 

restore factory settings

r4:

 Ad-hoc mode; reset and start with 

a standard IP address, settings 
available through customer service 
(RemoteVision modules only)

Button sounds on/off 

b0:

 Button sound off 

On (b1) 

b1:

 Button sound on 

Demo mode on/off 

n0:

 Demo mode off 

Off (n0) 

n1:

 Demo mode on 

Reviews: