Electrical connection AUS / NZ
The appliance is supplied with a mains
cable and moulded plug ready for con-
nection to an a.c. single phase
220 – 240 V 50 Hz supply. The plug rat-
ing is 15 amps.
All electrical work should be carried
out by a suitably qualified and com-
petent person in accordance with lo-
cal and national safety regulations.
Connection should be made via a
suitable switched socket which is
easily accessible. For extra safety it
is advisable to install a residual cur-
rent device (RCD) with a trip current
of 30 mA.
Do not connect the appliance to the
mains electricity supply by an extension
lead. Extension leads do not guarantee
the required safety of the appliance
(e.g. danger of overheating).
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow
= earth
Blue
= neutral
Brown
= live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings iden-
tifying the terminals in your plug, pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol (
z
) or
coloured green or green and yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter A or coloured
red.
WARNING
THIS APPLIANCE MUST BE
EARTHED
Electrical connection
23