Electrical connection

Installation, repairs and other

work by unqualified persons could
be dangerous.
Check that the voltage, frequency
and fuse rating shown on the data
plate match the household mains
supply.
The power outlet must be accessible
after installation. Do not use an
extension cord to connect the
dishwasher to the mains. Danger of
overheating! See data plate on the
right side of the door.
A damaged power cord must only be
replaced with a genuine Miele cord
by a Miele service technician.

Grounding instructions

THIS APPLIANCE MUST BE
GROUNDED.

In the event of a malfunction or
breakdown, grounding will reduce the
risk of electric shock by providing a
path of least resistance for the electrical
current. This appliance is equipped with
a cord having an equipment grounding
conductor and a grounding plug. The
plug must be plugged into an
appropriate outlet that is installed and
grounded in accordance with all local
codes and ordinances.

Improper connection of the

equipment grounding conductor can
result in electric shock.
Do not modify the plug provided with
the appliance; if it will not fit the
outlet, have a proper outlet installed
by a qualified electrician.
If there is any question concerning
the proper electrical connection or
grounding of this appliance to the
powersupply, please consult a
licensed electrician or call Miele’s
Customer Service Department:
USA: 1-888-99-MIELE(64353)
CDN: 1-800-565-6435

Specifications

The dishwasher comes equipped with a
4 ft (1.2 m) power cord (measured from
the rear of the dishwasher) with a
molded plug for connection to 120 V,
60 Hz, 15 A grounded receptacle.

Summary of Contents for G 5482 SCVi

Page 1: ...the country in which the dishwasher is being operated Connect the dishwasher to a drinking water supply The dishwasher may be connected to cold or hot water up to max 65 C supplies We recommend connecting to a cold water connection to reduce energy consumption If energy saving water heating sources such as solar energy circulation systems are used we recommend connecting to the hot water connectio...

Page 2: ...ressure reducing valve must be fitted Risk of damage from leaking water The connection point is subject to water pressure Water leaking from it can cause damage You should therefore open the faucet slowly and check for leaks Correct the position of the seal and screw thread if appropriate Risk of damage from leaking water The intake hose is under water pressure The intake hose must not be shortene...

Page 3: ...ot exceed 3 ft 1 m If the hose is to be directly connected to the drainage outlet on site use the supplied hose clip see the installation diagram The hose can be directed to the left or the right of the appliance The on site connector for the drain hose can be used for various hose diameters If the connector extends too far into the drain hose it must be shortened Otherwise the drain hose can beco...

Page 4: ...ystem must be vented Otherwise a siphoning effect during a program can cause the appliance to empty itself of water Open the dishwasher door fully Remove the lower basket Insert a screwdriver into the middle opening of the vent valve in the left wash cabinet wall Press the screwdriver further into the opening and push it through the membrane behind The vent opening for the water drain is now open ...

Page 5: ...e for the electrical current This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances Improper connection of the equipment grounding conductor can result in electric shock Do not modify the plug provided with the appliance i...

Page 6: ...trical supply This data must correspond to prevent machine damage Consult an electrician if in doubt GROUNDING INSTRUCTIONS THIS APPLIANCE MUST BE GROUNDED This appliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Prior to making ...

Reviews: