![Miele DGC 6705-1 Operating And Installation Instructions Download Page 162](http://html.mh-extra.com/html/miele/dgc-6705-1/dgc-6705-1_operating-and-installation-instructions_236080162.webp)
Frequently Asked Questions
162
Problem
Possible cause and solution
F 55
The maximum length of time for which the combi
steam oven can be operated on a function has been
exceeded, so the appliance has switched itself off au-
tomatically for safety reasons.
Switch the steam oven off and then back on again.
The steam oven is immediately ready for use again.
F 94
No water intake:
– the water intake hose is trapped or kinked.
Rectify the cause of the problem and start the ap-
pliance again.
– the water supply has been turned off.
Open the water supply stopcock and start the ap-
pliance again.
– one or both float switches in the water container are
stuck.
Release the float switches or switch so that it
moves freely.
If this fault message appears again after the prob-
lem(s) have been corrected, contact Miele Service.
F 190
The water intake valve is faulty.
This can occur if the control panel was opened or
closed during water intake.
Confirm with OK and continue operation.
If the same message appears again, call Miele
Service.
Summary of Contents for DGC 6705-1
Page 19: ...Overview 19 m Slide in compartment for water container n Water container ...
Page 189: ......
Page 190: ......
Page 192: ...M Nr 10 357 820 04 en US CA DGC 6705 1 DGC 6805 1 ...