Installation Instructions

DA 250-4  en-CA 
 
 

 
 
 
Installation, repair and maintenance work should be performed by
a Miele authorized service technician in accordance with national
and local safety regulations and the provided installation instructions. 

Summary of Contents for DA250-4

Page 1: ...tions DA 250 4 en CA Installation repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions ...

Page 2: ... hood This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists or to the ceiling joists directly Do not attach the plate directly to the ceiling with anchors toggle bolts etc Structural support 24 ...

Page 3: ...sehold electrical supply before installing the hood If there is any question concerning the electrical connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department See back cover for contact information WARNING THIS APPLIANCE MUST BE GROUNDED Important To increase security before the machine is installed it is recommended to i...

Page 4: ...Exhaust connection 6 150 mm diameter 1 Entrance for ductwork and power cord Appliance dimensions 26 ...

Page 5: ...ic cooktops 30 762 mm above gas cooktops 26 650 mm above an open electric grill or an open electric boiler fryer If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance Observe local building codes See Important Safety Instructions for further information CAUTION During the installation process please be careful of sh...

Page 6: ...before installing this hood Installation accessories 4 Screws 8 x 60 mm with 4 Washers for securing the ceiling plate S8 wall anchors included in the packaging are not for use in USA 2 Screws M 4 x 8 mm for adjusting the chimney 4 leveling plates for correcting an uneven ceiling 1 exhaust connector 1 hose clip for securing the ducting Installation 28 ...

Page 7: ...ng should be as short and straight as possible and the number of sharp bends should be minimized For most efficient air extraction the diameter of the ductwork should not be less than 6 150 mm Use of flat ducts also reduces the air extraction efficiency Noise levels of the hood will increase if flat ducts or round ducts of less than 6 150 mm in diameter are used Use smooth or flexible pipes made f...

Page 8: ...mportant If the ductwork runs through rooms ceilings garages etc where temperature variations exist it may need to be insulated to reduce condensation Condensate trap optional accessory In some cases a condensate trap may be required to collect and evaporate any condensation which may develop This optional accessory is available for ducts 5 125 mm and 5 7 8 150 mm in diameter When installing a con...

Page 9: ...Alteration rights reserved 3306 M Nr 06 850 870 00 en US ...