![Miele DA 9090 W Operating And Installation Instructions Download Page 27](http://html.mh-extra.com/html/miele/da-9090-w/da-9090-w_operating-and-installation-instructions_237246027.webp)
Installation
*INSTALLATION*
27
a
Ducting upwards or to the rear
b
Recommended area for the mains connection
c
A ducting outlet with
200 mm ensures sufficient space through the wall for
the ducting to flex
d
Ventilation grille for recirculation mode. The distance to the ceiling or to
furniture installed above the appliance should be at least 300 mm.
Vent connection
150 mm
* Installation with DADC 9000 tower (optional accessory). Note the possible area
for the ducting outlet in the accompanying installation diagram.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See “Warning and Safety” instructions for further information.
Cooking appliance
Minimum distance S
Electric hob
450 mm
Electric grill, deep fat fryer (electric)
650 mm
Multi-burner gas hob,
total output
≤
12.6 kW, no burner
>
4.5 kW
650 mm
Multi-burner gas hob,
total output
>
12.6 kW and
≤
21.6 kW,
no burner
>
4.8 kW.
760 mm
Multi-burner gas hob,
total output
>
21.6 kW,
or multi-burner gas hob where one burner
>
4.8 kW.
Not possible
Single burner gas hob, output
≤
6 kW.
650 mm
Single burner gas hob, output
>
6 kW and
≤
8.1 kW.
760 mm
Single burner gas hob, output
>
8.1 kW
Not possible