Cleaning and care
30
Replace the grease filters, making
sure that the locking clips are facing
down towards the hob.
If a grease filter is inadvertently
replaced upside down, insert a small
screwdriver blade into the slit to
disengage the clip.
Resetting the grease filter operating
hours counter
After cleaning, the operating hours
counter needs to be re-set.
Whilst the fan is switched on, press
the operating hours control
for
approx. 3 seconds, until only the
1
is
flashing.
The grease filter symbol
goes out.
If you want to clean the grease filter(s)
before the operating hours counter has
reached its maximum,
Press the operating hours control
for approx. 6 seconds, until only
the
1
is flashing.
Charcoal filter
If the cooker hood is connected for
recirculation, a charcoal filter must be
inserted in addition to the grease filters.
This is designed to absorb cooking
odours and is fitted in the canopy
above the grease filters.
Replacement charcoal filters can be
obtained from your Miele retailer or via
the internet at www.miele-shop.com.
See "Technical data" for type and
reference number.
Fitting and replacing the charcoal
filter
Before fitting or replacing a charcoal
filter, the grease filters must first be
taken out (see previous section for
instructions on how to do this).
Take the charcoal filter out of its
packaging.
Insert the charcoal filter into the back
of the charcoal filter frame, then push
up into the frame at the front.
Replace the grease filters.
When fitting for the first time, activate
the operating hours counter (see
"Operation").