The shaded areas 1) and 2) represent
the wall or ceiling area for the vent
cut-out, for feeding the connection
cable through to an external fan and for
fitting the connection socket.
Connection for air extraction
C
200 mm
Safety distance between cooktop and
rangehood (S)
When planning the installation height
of your rangehood, the
minimum
safety distance between the top of a
cooktop and the bottom of the
rangehood are as follows, unless a
greater distance is specified by the
manufacturer of your cooking
appliance:
600 mm above electric cooktops
650 mm above an open grill
or deep fat fryer,
650 mm above gas cooktops.
If this rangehood is installed above a
Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the rangehood.
See "Warning and Safety"
instructions for further information.
– Account should also be taken of the
height of the person who will be
using the rangehood most often. The
person should have sufficient space
to work comfortably at the cooktop,
and also be able to reach the
rangehood controls with ease.
– If positioned too high, extraction will
be inefficient.
– If you want the top of the rangehood
to be mounted flush with the ceiling,
make sure there is adequate space
below it for working. See
maximum/minimum appliance
height!
Appliance dimensions
25