The shaded areas 1) and 2) represent
the wall or ceiling area for the vent
cut-out, for feeding the connection
cable through to an external fan and for
fitting the connection socket.
Connection for air extraction
C
150 mm, or
C
125 mm with reducing
collar.
Safety distance between hob and
cooker hood (S)
When planning the installation height
of your cooker hood, the
minimum
safety distances between the top of
a cooker or hob and the bottom of
the cooker hood are as follows,
unless a greater distance is
specified by the manufacturer of
your cooking appliance:
450 mm (GB), 600 mm (AU, NZ)
above electric hobs and cookers,
650 mm above an open grill or deep
fat fryer,
650 mm above gas hobs and
cookers.
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See "Warning and Safety" instructions
for further information.