Installation
27
a
Extraction
b
Recirculation
c
Ventilation grille positioned at the top for recirculation
de
(only
d
is required for recirculation mode rangehoods):The shaded area
represents the wall or ceiling area for the vent cut-out and for fitting the
connection socket. Recirculation mode rangehoods only require an electrical
connection socket.
Connection for air extraction
150 mm, or
125 mm with reducing collar.
Safety distance (S)
The minimum distances between the top of a cooktop (excluding trivets, dials -
depending on model) and the bottom of the rangehood are as follows, unless a
greater distance is specified by the manufacturer of your cooking appliance.
See also "Warning and Safety instructions".
Cooking appliance
Minimum distance S
Electric cooktop
600 mm
Open electric grill
650 mm
Deep fat fryer (electric)
650 mm
Multi-burner gas cooktop with maximum 45.4 MJ/h
total output, with no burner having a greater output than
16.2 MJ/h.
650 mm
Multi-burner gas cooktop with total output greater than
45.4 MJ/h, or a gas cooktop including a single burner
with an output greater than 16.2 MJ/h.
760 mm
Single gas cooktop with a maximum output of 21.6
MJ/h.
650 mm
Single gas cooktop with a maximum output greater
than 21.6 MJ/h.
760 mm