Assembly parts
4 screws 8 x 60 mm
with
4 washers
and
4 plugs S 10
to secure the cover plate to the ceiling
The screws and plugs are designed
for use in concrete ceilings.
For other types of construction,
alternative suitable fixings will be
required.
Make sure the ceiling is strong
enough to bear the weight of the
cooker hood.
2 spring clips
to hang the cooker hood onto the cover
plate
4 countersunk screws M 6 x 20 mm
with locating bar and
4 self-locking nuts M 6
to secure the cooker hood to the cover
plate
1 cable clip
for securing the exhaust ducting to the
exhaust stub.
Before installation, it is important to
read the information given on the
following pages as well as the
"Appliance dimensions" and the
"Warning and Safety instructions" at
the beginning of this booklet.
This is particularly crucial when
using the cooker hood at the same
time as a heating appliance that
relies on oxygen from the same
room, which could result in the
build-up of toxic fumes.
Installation instructions
See enclosed Installation sheet for
instructions on how to install this
appliance.
Special installation
instructions for recirculation
mode
In order to use the cooker hood in
recirculation mode, it has to be fitted
with a special conversion kit which is
available from the Spare Parts
Department (see "Technical data"). It is
supplied with its own fitting instructions.
After the cooker hood has been
installed, the charcoal filter has to be
fitted, and the operating hours counter
has to be set.
Installation
26