Alteration rights reserved / 4804
M.-Nr. 05 889 281 / 04
en - GB
Page 1: ...structions Cooker hoods DA 362 DA 362 EXT DA 372 DA 372 EXT To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed or used for the first time GiW M Nr 05 889 281 ...
Page 2: ...ng and altering the operating hours counter 14 Cleaning and care Housing 16 Grease filter 16 Fitting and replacing the charcoal filter 18 Changing a lamp 19 Appliance dimensions 20 Installation Fitting the non return flap 22 Exhaust connection 22 Building in 23 Preparation for extraction 24 Preparation for recirculation 24 Connection for recirculation mode 24 Fitting the joystick 25 Joystick exten...
Page 3: ... incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance Please do not therefore dispose of your old appliance with your household waste Please dispose of it at your local community waste collection recycling centre and ensure that it presents no danger to children while being stored for disposal It ...
Page 4: ...cting the appliance to the mains supply make sure that the voltage and frequency details given on the data plate correspond with the on site electricity supply otherwise the appliance could get damaged Consult a qualified electrician if in any doubt The electrical safety of this appliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system whic...
Page 5: ...ter Fat particles drawn into the cooker hood present a fire hazard When using the cooker hood over a gas hob ensure that any burners in use are always covered by a pan otherwise flames could be drawn up by the suction of the cooker hood parts of which could then be damaged Always switch the cooker hood on when a cooking zone is in use otherwise condensation may collect in the hood which could caus...
Page 6: ...either should it be connected to ducting which ventilates rooms with fireplaces If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes seek professional advice Using at the same time as other heating appliances that depend on the air from the room Warning danger of toxic fumes Great care should be taken when using the cooker hood at the same time and...
Page 7: ...t If in any doubt the advice of a competent builder or for gas a Corgi installer must be sought If adequate ventilation can only be achieved through an open window a window contact switch must be fitted This ensures that the hood can only be operated when the window is opened wide enough The advice of a competent builder must be sought A window contact switch kit is available from good builders me...
Page 8: ...Description of the appliance 8 ...
Page 9: ...ning and Care to show how long the grease filter has been in use see Operation Filter operating hours counter to alter the number of hours counted by the filter operating hours counter see Operation To alter the grease filter operating hours counter i Touch control for the charcoal filters The indicator lamp for the charcoal filter touch control lights up when the recirculation mode charcoal filte...
Page 10: ...tly outside air recirculation with air recirculation conversion kit as an accessory The air is drawn in and cleaned first by the grease filter and then cleaned by charcoal filters The cleaned air is then recirculated back into the kitchen Before using the cooker hood in recirculation mode ensure that the charcoal filters are in place see Cleaning and care an external motor EXT models only The EXT ...
Page 11: ...ting indicator will light up To select a power level Press the joystick repeatedly to the right to select a higher power level and to the left to select a lower power level The relevant fan setting indicator will light up Depending on the intensity of cooking vapours levels I to III green indicator lamps are usually sufficient for normal cooking For short periods of intensive cooking vapours e g w...
Page 12: ...n It is advisable to run the fan for a few minutes after cooking is finished to neutralise any lingering odours in the air whether you are using air extraction or recirculation mode The fan can be set to switch off automatically after either 5 or 15 minutes After cooking is finished press the run on option touch control whilst the fan is still running Press once The fan switches off after 5 minute...
Page 13: ...rated for the number of hours set see Setting and altering the charcoal filter operating hours counter The charcoal filters must then be replaced with new ones After the new charcoal filters have been put in place the filter operating hours counter must be re set Press the charcoal filter touch control for about 3 seconds The indicator lamp for the touch control will go out Reading the filter oper...
Page 14: ... or 50 hours Switch the fan on with the joystick Press the run on option touch control and the grease filter touch control at the same time The indicator lamp for the grease filter touch control and one of the lamps for the power level touch controls will flash The power level touch control lamps show the time which has been set 1st lamp from the left 20 hours 2nd lamp from the left 30 hours 3rd l...
Page 15: ...ndicator lamp for the charcoal filter touch control and one of the power level touch control lamps will flash The power level touch control lamps show the time which has been set 1st lamp from the left 120 hours 2nd lamp from the left 180 hours 3rd lamp from the left 240 hours 4th lamp from the left unlimited Use the joystick to select the time required Press to the left for a shorter operating ti...
Page 16: ... agents containing soda acids chlorides or solvents abrasive cleaning agents e g powder cleaners or cream cleaners and abrasive sponges as well as pot scourers or sponges which have been used previously with abrasive cleaning agents These will damage the surface material The controls may suffer discolouration or damage if soiling is left on them for too long Remove any soiling straight away E Clot...
Page 17: ...in any way After cleaning leave the filter to dry for a while on an absorbent surface before putting it back in place When removing the filter for cleaning also clean off any residues of oil or fat from the now accessible housing to prevent the risk of these catching fire When putting the grease filter back in position ensure that the locking clip is visible facing down towards the hob Should the ...
Page 18: ... the old filters and replace with the new ones as illustrated Replace the grease filter When fitting for the first time Set the operating hours counter to suit your requirements see Operation Filter operating hours counter Always replace the filters immediately if the lamp for the charcoal filter touch control comes on or if they are no longer effective in absorbing kitchen odours They should howe...
Page 19: ...as been carried out Exercise caution when changing halogen lamps They get very hot during use and remain hot for some time after being switched off Please follow the manufacturer s instructions Remove the grease filter from the cooker hood Loosen the halogen lamp securing screw slightly and push downwards see illustration Tighten up the screw again Turn the halogen lamp anti clockwise and pull it ...
Page 20: ... Cut out dimensions A depth T of at least 40 mm must be provided at the back of the building in niche Appliance dimensions 20 ...
Page 21: ... Cut out dimensions A depth T of at least 40 mm must be provided at the back of the building in niche Appliance dimensions 21 ...
Page 22: ...bove electric cookers hobs may be preferable to give more working space Fitting the non return flap Air extraction mode only not for operation with an external motor If a non return valve is not present in the venting system the non return flap supplied must be fitted onto the exhaust stub in the motor unit The flaps must open upwards Turn the non return flap slightly anti clockwise to secure it E...
Page 23: ...Building in The cooker hood is intended to be built into wall units cooker hood housing units and above breakfast bars or island areas Check prior to installation that the top of the appliance will be accessible after installation If this is not the case install the exhaust ducting and prepare the electrical connection and the connection to the external motor EXT models only before installation Pl...
Page 24: ...onversion kit for recirculation mode C 125 mm Exhaust grille ducting hose clip 2 charcoal filters see Technical data Connection for recirculation mode When fitting the cooker hood in a wall unit the exhaust grille b has to be fitted in the top of the wall unit The exhaust stub a and the exhaust grille b are joined together using a suitable hose or flexible ducting c If the front of the unit is cei...
Page 25: ... allen key Whilst doing so counterhold the base of the joystick with an SW 9 spanner but do not turn Joystick extension The joystick can be extended if required Whilst counterholding the base of the joystick with an SW 9 spanner do not turn secure the joystick extension to the stub using a spring washer in between them as shown above Then attach the lower section of the joystick as previously desc...
Page 26: ...l motor Connect the appliance to the mains via a fused spur or fused socket as appropriate Before connecting the appliance read the safety notes in Warning and Safety instructions and Electrical connection Before using the appliance for the first time take the grease filter out and remove the protective foil from the filter frame Then replace the grease filter Installation 26 ...
Page 27: ...e cooker hood would increase and extraction would be less efficient Only reduce the diameter of the ducting if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable materials for extraction connection Where ducting is horizontal it...
Page 28: ...be addressed The exhaust ducting will need to be suitably insulated Condensate trap In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection Connection for air extr...
Page 29: ...olator or a double pole fused spur connection unit which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in When switched off there must be an all pole contact gap of 3 mm in the switch including switch fuses and relays according to EN 60 335 If the switch is not accessible after installation depending on coun...
Page 30: ... Department see back cover for address When contacting your Dealer or the Service Department please quote the model and serial number of your appliance These are shown on the data plate which is visible when the grease filter is removed Please note that telephone calls may be monitored and recorded to improve our service After Sales Service 30 ...
Page 31: ...tensive level 560 m3 h Extraction system C 100 mm Level I 200 m3 h Level II 330 m3 h Level III 380 m3 h Intensive level 440 m3 h Unrestricted 650 m3 h Recirculation with charcoal filter Level I 160 m3 h Level II 240 m3 h Level III 300 m3 h Intensive level 360 m3 h Depending on installation Miele Active charcoal filter DKF 2 For EXT models the connected load and extraction power will depend on the ...
Page 32: ...Alteration rights reserved 4804 M Nr 05 889 281 04 en GB ...