Recirculation connection
^
DA 362-75:
In recirculation mode, one cut out
must be made, where the ducting
ends, for the installation of the
recirculation vents,
b
.
If installing the hood over an island or
in a cabinet at ceiling height, a
suitable cut-out has to be made in
the front panel,
d
.
^
DA 362-110:
In recirculation mode, 2 cut outs must
be made, where the ducting ends, for
the installation of the recirculation
vents,
b
.
If installing the hood over an island or
in a cabinet at ceiling height, a
suitable cut-out has to be made in
the front panel,
d
.
^
The exhaust connection,
a
, and the
recirculation vent,
b
, are joined
together with a pipe or flexible duct,
c
, cut to size.
When installing the recirculation
vents make sure that the slats point
towards the center of the room and
not to a wall or the ceiling.
^
Install the active charcoal filters (see
"Cleaning and Care").
Installation
32