To adjust the incline on the canopy:
Slightly loosen fixing screws
b
again.
Slightly loosen adjusting screws
c
(SW 7).
Lower or raise the canopy at the
front by hand into the correct posi-
tion.
Using the other hand tighten the ad-
justing screws
c
(SW 7) up again.
Tighten the fixing screws
b
securely.
Motor unit
(not when operating the external fan)
If a non-return flap is not present in
the venting system, the
non-return
flap
supplied must be fitted into the
exhaust connection in the motor unit.
The flaps must open upwards.
The cooker hood is designed to take
ø 150 mm exhaust ducting.
If 125 mm ø exhaust ducting has to
be used the
reducing collar
needs
to be fitted into the exhaust connec-
tion on the motor unit.
(see "Connection for air extraction".