en - PWM 514
35
Technical data
Voltage versions and electrical data
3N AC 400 V, 50/60 Hz, EL A01Z
Supply voltage
3N AC 400V 50/60Hz
Frequency
50/60 Hz
Required fuse rating (on site)
16 A
Power rating
9,6 kW
Connection cable, min. cross-section
2,5 mm²
Cable gland
3N AC 400 V, 50/60 Hz, RH
Supply voltage
3N AC 400V 50/60Hz
Frequency
50/60 Hz
Required fuse rating (on site)
16 A
Power rating
9,6 kW
Connection cable, min. cross-section
2,5 mm²
Cable gland
3N AC 400 V, 50/60 Hz, EH
Supply voltage
3N AC 400V 50/60Hz
Frequency
50/60 Hz
Required fuse rating (on site)
16 A
Power rating
2,3 kW
Connection cable, min. cross-section
1,5 mm²
Cable gland
3 AC 230 V, 50/60 Hz, EL B04Z
Supply voltage
3 AC 230V 50/60Hz
Frequency
50/60 Hz
Required fuse rating (on site)
35 A
Power rating
9,6 kW
Connection cable, min. cross-section
4 mm²
Cable gland
Plumbing
Models with detergent drawer (DD)
Permitted flow pressure
1000 kPa
Maximum intake rate
47,5 l/min
Cold water connection
(to be provided on site, male thread according to DIN 44991, flat seal)
3 x ½” with ¾” threaded union
Optional hard water connection, cold
(on-site external thread according to DIN 44991, flat seal)
2 x ½” with ¾” threaded union (optional)
Hot water connection (≤ 70 °C)
(on-site external thread according to DIN 44991, flat seal)
1 x ½” with ¾” threaded union
Length of inlet hoses supplied
1,55 m