Problem solving guide
80
Water inlet fault
Problem
Cause and remedy
The optical in-operation
indicator light is flash-
ing quickly.
The alarm tone is
sounding.
One of the following
messages appears in
the display:
Open stopcock
The stopcock is closed.
Open the stopcock fully.
Water intake
Before rectifying the problem:
Switch the dishwasher off.
The water inlet is restricted.
Open the stopcock fully and start the programme
again.
Clean the filter in the water inlet (see “Cleaning
and care” chapter, “Cleaning the filter in the water
inlet” section).
The water-connection pressure is lower than
50 kPa.
Seek professional advice.
The on-site connection for the water drainage may
be too low and you will need to vent the water
drainage (see “Installation” chapter, “Water drain-
age” section).
The following fault mes-
sage appears during the
SolarSave
programme:
Intake temperture too low
The inlet water has not reached the required temper-
ature of 45 °C (see “Installation” chapter, “Water inlet”
section).
Start the programme again.
If the fault message appears again, select a differ-
ent programme.