Umbau- und Montageanweisung
M.-Nr. 06702862
7 von 22
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
06.01.2022
A
Press the
Save button.
The module is signed on.
A
Select the menu option
Service settings
>
Basic settings
>
Dispensing
.
A
Set the
Dispensing
menu option to the
on
parameter value.
A
Press the
Save button.
A
Quit customer service mode.
A
Switch the appliance off and on again.
Signing on the dispenser pumps
A
Switch to the supervisor level.
A
Select the menu option
Settings
>
Dispenser calibration
>
Dispenser pump 1
.
A
Disconnect the hose at the pressure side from the dispenser pump.
A
Place the dispenser pump hose at the pressure side in a measuring vessel.
A
Press button 0/1.
The pump runs for 60 s.
A
Measure the dispensing quantity in the measuring vessel and enter it on the display at
V:. . . ml
.
A
Press the
Save button.
A
Select the next pump. Repeat the process to calibrate all the pumps.
Registering a container empty signal
A
Select the
Dispenser level reminder
menu option.
A
Select the
Dispenser pump 1
menu option and set the parameter value to
yes
.
A
Select the next pump and repeat the setting process until all the dispensing pumps are registered.
Performing a functional test and safety checks
A
Perform a functional test and safety checks.
A
Check the water connections and dispensing system for leaks.
A
Reinstall the cover plate over the electrical connection and the machine lid.