MAR-800P
Midtronics B.V. Hoofdveste 6–8 Houten NL
www.midtronics.com
17
Chapter 6: Generate Pair
Chapter 6: Generate Pair
With generate pair you can test whether two batteries can be
used together.
1. Select the battery type.
1
FLOODED LEAD ACID
2
AGM FLAT
3
AGM SPIRAL
4
GEL
Press the NEXT soft key to continue. The BACK soft key
returns you to the Main Menu at the start of the test and
to the previous screen as you progress.
2. Select the rating units.
1
MCA
5
DIN
2
EN
6
SAE
3
CCA
7
IEC
4
JIS
Battery Standards
Rating
System
Description
Range
MCA
Marine Cranking Amps
100 to 2000
EN (A)
European Norm
100 to 2000
CCA
Cold Cranking Amps (specified
by SAE): The amount of
current a battery can provide at
0 ºF (–17.8 ºC).
100 to 2000
JIS
Japanese Industrial Standard:
(shown on a battery as a
combination of numbers and
letters)
73 numbers
from 26A17
to 245H52
DIN (A) Deutsche Industrie-Norm
100 to 1250
SAE (A) European labeling of CCA
100 to 2000
IEC (A)
International Electrotechnical
Commission
100 to 1250
If you select JIS, the analyzer asks for the JIS part number.
Scroll to the part number. To increase your scrolling speed,
hold the UP (
) or DOWN (
) ARROW key, or use the
LEFT (
) or RIGHT (
) ARROW key to move up or down
four part numbers at a time.
Press the NEXT soft key to continue.
3. Press an UP (
) or DOWN (
) ARROW key to select the
BATTERY RATING.
550
CCA
Press ENTER.
4. Hold the bottom of the tester five centimeters above
the battery case so that the IR temperature sensor on its
underside can approximate the battery temperature.
Press NEXT to lock in the battery temperature.
5. Connect to the reference battery and press NEXT.
6. When the tester detects an insufficient charged or bad
battery the tester asks you to connect another battery.
Press NEXT.
7. In case of a good battery, connect to battery 2 of 2 and
press NEXT.
Pair Test Result
Decision
Recommended Action
and Information
GOOD PAIR
Return the pair to service
CHARGE PAIR
Fully charge the pair and return it to
service.
REPLACE PAIR
Replace the pair. A REPLACE
PAIR result may also mean a poor
connection between the battery
cables and the battery. After taking
the battery out, retest the battery
using the OUT OF VESSEL test
before replacing it.
OUT OF BALANCE
The batteries used in the pack do
not have the same state of charge
and/or the same state of health. This
means the testers are not in balance
and this can result in a non properly
functioning battery pair. Follow the
tester’s instructions.