background image

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

15

7: Settings

JDT-1

Languages

Use the Language & Input function to select the 

default system language used by the tool.  User 

defaults also include Test Results, Email, and Print 

languages.

System Language

Select the default standard language for the analyzer to use 

on the tester.

Test Result Language

Select the default language for the analyzer to use for all tests 

and results displayed on the tester.

Email Language

Select the default standard language for the analyzer to use for 

all tests and results sent via email.

Print Language

Select the default standard language for the analyzer to use for 

all tests and results printed using a networked printer.

Display

Adjust the tester display including the Brightness, 

Sleep Time, and Dim Time.  Auto Brightness can also 

be turned on and off.

Brightness

Adjust the display Brightness by tapping and holding the 

slider, then moving it right or left to make the screen brighter 

or darker.

Auto Brightness

Enable and disable Auto Brightness by taping on the check box.

Sleep Time

Adjust the amount of elapsed time before the tester goes into 

a power saving (Sleep) mode.  Default = 2 minutes.

Dim Time

Adjust the amount of elapsed time before the tester goes into 

a power saving (Dim) mode.  Default = 1 minute.

BMIS

Enter and edit BMIS Login and Password information.  

Log into a BMIS account.

User Name 

[email protected]

Password 

• • • • • •

Shop Information

Access default Shop Information including Store 

Name, address, and phone number.  Also access 

battery test defaults including rating, temperature 

units, and decimal separator. Use also to adjust the 

tester date and time settings.

Settings Home

Date/Time Settings

Test Settings

Create MDCA Log File

Shop Information

Use the onscreen keypad to enter the store name, address, and 

phone number.

Store Name

Midtronics

State

IL

Street Address

7000 Monroe

Zipcode

60527

Street Address 2

Phone #

1-630-323-2800

City

Willowbrook

Date/Time Settings

1.  Tap 

 to access the Date/Time setting defaults.

Select Time Format

12 Hour

Set Date

Select Date Format

3/18/2018

Set Time

Select Time Zone

EST

Select Time Format

12 or 24 Hour Format

Select Date Format

Month/Day/Year, Day/Month/Year, or Year/Day/Month

Select Time Zone

Time zone in which the analyzer will be operated.

Set Date

Tap 

 or 

 to enter the month, day, and year.  Tap Set to 

save the date or Cancel to exit without saving.

Sep

17

2015

Oct

18

2016

Nov

19

2017

CANCEL

SET

Summary of Contents for JDT-1 WM

Page 1: ...Users Guide November 2019 167 000938EN A JDT 1 WM Battery Diagnostic Service System For testing 6 and 12 volt automotive 12 volt and 24 volt charging systems For Technical Support call 866 592 8052...

Page 2: ......

Page 3: ...12 Totals By Test Type 12 Totals By Date And Location 12 Vehicle History 12 Vehicle Select Option 12 6 Messages 13 Accessing Messages 13 Message Types 13 7 Settings 14 WiFi 14 Adding A Network 14 Dele...

Page 4: ......

Page 5: ...ing soda Always wear proper safety glasses or face shield when working with or around batteries Keep hair hands and clothing as well as the analyzer cords and cables away from moving engine parts Remo...

Page 6: ...ectrolyte level is too low add distilled water to fill up to above the top of the plates and fully charge the battery Do not overfill Corroded or loose battery tray and hold down fixture Tighten or re...

Page 7: ...i successfully connnected screen 4 Select Time Zone 5 Select the correct Date Time 6 Select the correct Walmart store from the displayed list 7 Confirm the store information is correct and tap Next 8...

Page 8: ...ecommended scanning procedures and VIN scanning help Manual Entry Use the on screen keypad to manually type the 17 digit VIN and tap Next 1 2 3 4 5 6 7 8 9 0 W E R T Y U P A S D F G H J K L Z X C V B...

Page 9: ...ible test results System Test 1 Tap to proceed with the System Test 2 Start the engine and let it idle 3 Tap Next The analyzer tests the alternator output 4 When prompted rev the engine to between 200...

Page 10: ...hicle Year Test Location Vehicle Make Rating Units Vehicle Model Battery Rating Vehicle Technology Battery Installation 4 Use the Viewing Window to align the temperature sensor over the battery and ta...

Page 11: ...g lists to select the year make and vehicle model If applicable a list of optional original equipment is displayed Use Manual Entry if the battery being tested is not listed Tap to continue to the Edi...

Page 12: ...en Weld Replace Charge Retest Temp Sensor Failed Replace Battery Aborted Badcell Short Replace Invalid Test Totals By Test Type Displays test totals by test type In Vehicle Test After New Battery Inst...

Page 13: ...to the Main Menu Accessing Messages A number is displayed next to the Messages icon when the analyzer has received any critical messages The number does not include non critical Notifications Unread C...

Page 14: ...Displays all entered email addresses Addresses can be added edited and deleted Admin Only Entered email accounts are added to the email address book Frequently used email addresses can be selected fro...

Page 15: ...time before the tester goes into a power saving Sleep mode Default 2 minutes Dim Time Adjust the amount of elapsed time before the tester goes into a power saving Dim mode Default 1 minute BMIS Entera...

Page 16: ...parators Create MDCA Log File The MDCA function is used by Midtronics technical support 2 Tap to return to the Shop Information screen Accessories Displays connected and linked accessory devices Addit...

Page 17: ...soline Electric Start Stop Hybrid Start Stop Diesel Battery Installation Single Battery or Dual Batteries Battery Application Automotive Marine Powersport Group 31 Commercial 4D 8D Lawn and Garden Bat...

Page 18: ...ery shows good cranking performance but low charge and low reserve capacity performance Low reserve capacity will compromise the battery s ability to provide power to the vehicle and hold a charge ove...

Page 19: ...eplace if necessary and retest If the belts and connections are in good working condition replace alternator or external voltage regulator LOW OUTPUT Alternator not providing enough current to power e...

Page 20: ...r left portion on the back of the Controller handle Flashlight Camera Hold Steady Hold Controller steady when scanning the VIN barcode This allows the user to clearly see the bar code and allows the c...

Page 21: ...Midtronics Inc 7000 Monroe Street Willowbrook IL 60527 www midtronics com 21 Appendix C Recommended Test Procedure JDT 1...

Page 22: ...Midtronics Inc 7000 Monroe Street Willowbrook IL 60527 www midtronics com 22 Appendix C Recommended Test Procedure JDT 1...

Page 23: ...Midtronics Inc 7000 Monroe Street Willowbrook IL 60527 www midtronics com 23 Appendix C Recommended Test Procedure JDT 1...

Page 24: ...anadian Inquiries TollFree 118665928052 Midtronics b v European Headquarters Houten The Netherlands Serving Europe Africa the Middle East and The Netherlands Phone 31 306 868 150 Midtronics China Chin...

Reviews: