Midtronics Ford CPX-950 Quick Reference Card Download Page 2

Midtronics BV.     Hoofdveste 6-8   3992 DG Houten   Netherlands

www.midtronicseurope.com

Page 

2

Quick Reference Card

167-000930EN-A

JUN 2019

24V System Test

Make a selection: Battery Test or Generate Pair

Battery Test

1.  Battery Test Setup - 

Edit the displayed vehicle and battery in-

formation. 

2.  Temperature

 - Hold the tester temperature sensor over  

 

the battery being tested. Select 

Capture

 to lock in the live tempera-

ture

3.  You are requested to connect to the second battery. If there’s 

only 1 battery, this step is automatically skipped. 

4.  Temperature - you are requested to aim the temperature sen-

sor at the second battery. Then click ‘Capture’ The test is start-

ed.

5.  The result is shown, through which you can select ‘System Test’ 

, ‘Send Results’ or ‘Done’ to return to the mainscreen. 

Generate Pair

1.  Battery Test Setup - 

Edit the displayed vehicle and battery in-

formation. 

2.  Temperature

 - Hold the tester temperature sensor over  

 

the battery being tested. Select 

Capture

 to lock in the live tempera-

ture

3.  If the battery is in a good state, you are requested to con-

nect the CPX to the second battery. If the first battery needs 

a charge a warning is shown, asking the user to connect a dif-

ferent battery to test or charge the battery. A pair cannot be 

generated with discharged batteries. 

4.  Temperature - you are requested to aim the temperature sen-

sor at the second battery. Then click ‘Capture’ The test is start-

ed.

Test Results

Send test results via 

email.

6

Print test results

Icons are color-coded to indicate status.

  Battery Test

  Starter Test

  Alternator Test

Green:

All test parameters 

were completed and 

have passed.

Red:

The battery has 

failed the test.

Yellow:

Some test parameters 

may require further 

testing.

Gray:

Insufficent data to 

perform the test.

Test Results - Summary

Good Battery

Cranking Normal

Charging Normal

Send Results

Done

Test Results - Summary

The Test Results - Summary screen is displayed following a System Test.  

Select the Battery, Cranking, or Alternator Test to view detailed test 

results for each part of the test.
To send the test results to a configured printer or via email select 

Send 

Results.  

To return to the Home Screen, select 

Done

 to the Main Menu.

Tap the icons at the top of the screen to view specific test results.
Refer to Appendix B: Decision Tables in the User Manual for a complete 

explaination of all possible test results.

Willowbrook, IL USA
Phone: 1.630.323.2800

Canadian Inquiries
Toll Free: +1 1 866 592 8052

MIDTRONICS HEADQUARTERS

MIDTRONICS B.V. EMEA

MIDTRONICS CHINA

MIDTRONICS INDIA

European Headquarters
Houten, The Netherlands
SerVIDg Europe, Africa, the Middle East
Phone: +31 306 868 150

China Operations 
Shenzhen, China
Phone: +86 755 2374 1010

Navi Mumbai, India
Phone: +91 22 27564103/1513 

Asia/Pacífic (excluding China) 
Contact Corporate Headquarters 
Phone: +1.630.323.2800

167-000930EN-A  19 JUNE  

©

2019 Midtronics, Inc. All rights reserved.

www.midtronicseurope.com

Reviews: