2
Quick Reference Guide
167-000840EN-B
October 2018
www.midtronics.com
Corporate Headquarters
Willowbrook, IL USA
Phone: 1.630.323.2800
Canadian Inquiries
Toll Free: +1 1 866 592 8052
Midtronics b.v.
European Headquarters
Houten, The Netherlands
Serving Europe, Africa, the Middle
East, and The Netherlands
Phone: +31 306 868 150
Midtronics China
China Operations
Shenzhen, China
Phone: +86 755 2374 1010
Midtronics India
Navi Mumbai, India
Phone: +91 22 2756 4103/1513
Contact Corporate Headquarters
Phone: +1.630.323.2800
Asia/Pacífic (excluding China)
4. Temperature
- Hold sensor 6 to 12 inches over battery & se-
lect
Capture
.
5. VIN Capture
- (optional) Scan VIN bar code, usually located
in the right corner of the vehicle’s front windshield or on the
driver’s side door frame.
Manual Entry
: Use the on-screen keypad to manually type
the 17-digit VIN and tap
Next
.
6. Battery Test Setup
- Edit vehicle and battery information
based on the VIN & select
Start
.
Application
Automotive, 4D/8D, Group 31
Battery Post
Top Post, Side Post
Battery Type
Flooded, EFB, AGM Spiral, AGM, Gel
Battery Units
CCA, MCA, CA, DIN, SAE, EN, EN2
Battery Rating Hold
or
to increase scrolling speed.
Battery Test Results
Send test results via
email.
Continue to System
Test
6
Print test results
Return to Main Menu
Icons are color-coded to indicate status.
Battery Test
Starter Test
Alternator Test
Green:
All test parameters
were completed and
have passed.
Red:
The battery has
failed the test.
Yellow:
Some test parameters
may require further
testing.
Gray:
Insufficent data to
perform the test.
Refer to Appendix B: Decision Tables in the User Manual for a
complete explaination of all possible test results.
System Test
1. Start the vehicle’s engine and let it idle.
2. Ensure all accessories (High Beam headlights/ventilation
blower etc.) are off and select
Next
.
The analyzer tests the alternator output.
3. When prompted, rev and hold the engine to between 2000
to 3000 rpm.
The analyzer tests the alternator output again.
4. When prompted Idle the engine and and select
Next
.
5. Turn on the high beam headlights and ventilation blower.
6. Select
Next
.
The analyzer tests the alternator output.
7. When prompted, rev and hold the engine to between 2000
to 3000 rpm.
The analyzer tests the alternator output again.
8. When prompted Idle the engine and and select
Next
.
System Test Results
Test Results - Summary
Good Battery
Cranking Normal
Charging Normal
Send Results
Done
Test Results - Summary
The Test Results - Summary screen is displayed following a
System Test. Select the Battery, Cranking, or Alternator Test to
view detailed test results for each part of the test.
To send the test results to a configured printer or via email select
Send Results.
To return to the Home Screen, select
Done
to the
Main Menu.
Tap the icons at the top of the screen to view specific test results.
Refer to Appendix B: Decision Tables in the User Manual for a