Mido R718PA4 User Manual Download Page 5

4

 

MinTime = 1min, MaxTime = 1min 

Downlink: 0157003C003C0000000000 
Device returns:

 

8157000000000000000000 (configuration is successful)

 

8157010000000000000000 (configuration is failed)

 

(2) Read configuration parameters

Read device parameters

Downstream: 0257000000000000000000

 

Device returns: 8257003C003C0000000000 ( To read current report configuration parameter)

 

6.Installation

This product comes with a waterproof function.

 

When using it, users can attach the back side to the iron surface, or use screws to fix both ends to the wall. Note: 

To install the battery, use a screwdriver or similar tool to assist in opening the battery cover.

 

1. The device has

 

a

 

built-in magnet (as shown

below). It can be attached to the surface of an iron

 

object when it is installed, which is convenient and

 

quick. In order to make the device installation

 

more secure, use screws (purchased) to fix the

 

device to the wall or other surface (such as the

 

installation diagram). The device is screwed in -

 

two screws in the middle (purchased by users).

 

Do not install the device in a metal shielded box or

 

in an environment with other electrical equipment

 

around  it  to  avoid  affecting  the  wireless

 

transmission of the device.

 

2. The device periodically reports the data
according to Max Time. The default Max Time
is 1 hour. Note: Max Time can be modified by
the downlink command, but it is not
recommended to set this time too small to avoid
excessive battery drain.

3. The device can be used in scenarios such
as:

 

 

 

 

Sewer

 

Pig farm

 

Chemical plant

 

Wastewater treatment 
plant

 

Exploration drilling channel

 

Reviews: