Troubleshooting Reference for the PROwatt SW 1000 

Sine Wave Inverter 

 

Troubleshooting Reference 

Condition 

Possible Cause 

Solution 

E01 

Under voltage shutdown 

Recharge battery and check 

connections 

E01 with persistent low 

battery alarm 

Poor DC wiring/ battery 

condition 

Use proper and secure wiring; 

charge or install new battery 

E02 

Over voltage shutdown 

Check if connected to 12 V 

battery system 

E03 

Overload shutdown 

Reduce load 

E04 with heavy load 

connected 

Over temperature shutdown 

Cool down inverter and reduce 

load 

E04 with normal load 

connected 

Over temperature shutdown 

Improve ventilation 

E10 no output voltage 

Short circuit; heavy load; 

output circuit overheat 

Check for short circuit; remove 

load; turn unit off and cool 

No output voltage; no 

voltage indication 

Unit is off; No power to 

inverter; Inverter fuse open; 

Reverse DC polarity 

Turn device on; check wiring; 

replace fuse if necessary; check 

polarity 

Unit is on but no AC output 

GFCI device tripped 

Reset the GCFI 

Table A.3

: Power Inverter Troubleshooting Reference

 

Summary of Contents for Solar Classic 150

Page 1: ...light Volts 4 Press Enter 5 Make sure the Equalize Absorb and Float voltages are 30 6 V 29 2 V and 27 0 V respectively Figure A 1 Programmed Voltage Settings 6 If the voltages do not match up highligh...

Page 2: ...the programmed time is not two hours scroll to the right and highlight the time under EQ 7 Adjust the equalizing time using the up and down arrow keys 8 Press Enter to save the time 9 Press Status to...

Page 3: ...inside the breaker box next to the kitchen door Figure A 4 Kitchen Freezer and Lights Circuit Breakers 3 Turn off the circuit breakers for the solar panel and the charge controller connections inside...

Page 4: ...when EQ Started is highlighted Figure A 6 Equalization Start Interface 8 Press Status to return to home screen 9 On the home screen the bottom right corner should say EQ 10 To stop a manual equalizati...

Page 5: ...n the inverter 2 Press the power switch button for one second to turn off the inverter 3 If you are not planning on recharging the battery within a week or so turn the inverter off 2 Indicator LEDs 1...

Page 6: ...e shutdown Red E03 Over load shutdown Red E04 Over temperature shutdown Red E10 Short circuit or output overheat Table A 1 LED and Digital Display Codes Operating Limits Input Voltages Operating Condi...

Page 7: ...e power should turn off For example if the lamp goes out it is functioning correctly If the lamp remains lit or the reset button does not pop out the GCFI may not be functioning If the GCFI trips by i...

Page 8: ...56 Figure A 9 Power Inverter DC Terminals...

Page 9: ...utdown Reduce load E04 with heavy load connected Over temperature shutdown Cool down inverter and reduce load E04 with normal load connected Over temperature shutdown Improve ventilation E10 no output...

Page 10: ...influence on functionality 3 Digital display of the battery voltage 4 Represents the wind turbine providing power generation if there is a solar panel connected there will be a solar panel icon 5 Rep...

Page 11: ...this to decrease parameter values by increments of 0 1 Esc Press this button to exit the setup interface and save the modified parameters Table A 4 LED Reference Maintenance 1 Clean the exterior of t...

Page 12: ...60 Figure A 12 Under Voltage Reference 6 Ensure that the over voltage is around 15 0 volts Figure A 13 Over Voltage Reference...

Reviews: