1 3 | Page
1 0-293-1 REV E
The Brat Solar Charge Controller Instructions
Troubleshooting
Problem
Possible Cause(s)
Solution
Batteries do not charge
Incorrect system Voltage selected
Set S1 -3 to correct system voltage
Not enough sunlight reaching the panels
Reposition panels, check for shading
wiring error
Verify all connections
Ratings
Max PV Voltage in
60 Volts DC
Max Output
30 Amps DC Configurable as 20 Amps charge and 1 0 Amps load or as
30 Amps charge only.
Thermal Shutdown
85°C restarting at 55°C
Low Voltage Disconnect:......................... 1 2V Setting........................ 24V Setting
Light/Shallow discharge.......................... 11 .7V..................................23.4V
Deep Discharge...................................... 11 .0V..................................22.0V
Reconnect ........................................... 1 2.6V................................. 25.2V
Glossary
Absorb............................... A charging state where the battery is held at the absorb volt setting for 2 hours.
Amp................................... A measurement of electrical current.
Amp-Hour.......................... A measurement of electrical power. Amps x Hours.
Auto-EQ............................. An equalization charge that will attempt to start every thirty days.
AWG.................................. American Wire Gauge.
BATT..................................Battery or Battery Bank.
Bulk....................................A charging state where all available power goes to the battery until it reaches
the Absorb voltage setting.
EMI.................................... Electro Magnetic Interference. Electrical noise.
EQ..................................... Equalization charge. An extended charge to match charge level on battery cells.
Float...................................A charging state to maintain a fully charged battery.
LED....................................Light Emitting Diode.
LVD.................................... Low Voltage Disconnect.
OVD................................... Over Voltage Disconnect.
Minus................................. Negative power connection
Parallel...............................A mode where the Load circuit is used to increase The Brat's charging capacity.
Plus....................................Positive power connection.
PV...................................... PhotoVoltaic.
PWM.................................. Pulse Width Modulation. How The Brat maintains regulation.
Solar Clock........................ The ability of The Brat to estimate time of day. Used with the load function.
Temp Compensation
Charging voltage adjustments made by The Brat based on Ambient
temperature.
Three Stage Charging....... A charging scheme for batteries with three levels of charging.
Watt................................... Instantaneous power. Amps x Volts = Watts.
Watt-Hour.......................... A measurement of electrical power. Watts x Hours = Watt-Hours.