Radio Disable & Radio Enable:
If a radio becomes lost or stolen or the user does not pay for access, the
speaker microphone can be “disabled”, so it will no longer key the radio or pass receive audio from the radio.
When disabled it will still respect Query, Polling and Spy commands. If the radio is found it can then be
Spy (Remote Monitoring):
When the Spy command is received by the unit it will PTT the radio and pass audio
from the microphone to the radio for transmission. The length of time of this transmission is programmable for 15
seconds, 30 seconds, 45 seconds or 60 seconds.
Emergency Acknowledge:
If the unit is programmed to send the Emergency ANI continuously or for multiple
times, the receipt of the Emergency Acknowledge command from the CAD-800 will cause the unit to stop the
emergency sequence and no longer send Emergency ANIs.