Midian Electronics TS-120-VX1 Manual Download Page 1

1

TS-120-VX1 

Multi-Format ANI Encoder with Lone Worker & Man-Down 

Manual Revision:  2013-04-03 

Covers Software Revisions: 
VS-1XXX

: 01.53.00 & Higher 

Covers Hardware Revisions: 
VS-VX1

: D & Higher 

This manual & product supports the following radios: 

Portables: 

VX-350, VX-410, VX-420, VX-450, VX-460, VX-600, VX-800, VX-820, VX-900, VX-920 

Mobiles: 

VX-2100, VX-2200, VX-4000, VX-4100, VX-4200, VX-4500, VX-4600, VX-5500, VX-6000 

Summary of Contents for TS-120-VX1

Page 1: ...s Software Revisions VS 1XXX 01 53 00 Higher Covers Hardware Revisions VS VX1 D Higher This manual product supports the following radios Portables VX 350 VX 410 VX 420 VX 450 VX 460 VX 600 VX 800 VX 8...

Page 2: ...C Frequency Response 300 3000 Hz Input Impedance 45 k Input Level TX 0 05 2 5 VPP Input Level RX 0 05 2 5 VPP Audio Output Impedance 1200 Ohm INSTALLATION OVERVIEW 1 Test the radio for functionality 2...

Page 3: ...gency conditions Assign calls fairly The TS 120 offers ANI Emergency ANI in Motorola s MDC 1200 Kenwood s FleetSync Harris G Star aka GE Star DTMF and 5 tone The TS 120 can be used with Midian s ADD C...

Page 4: ...After entering the parameters save the file by going to File Save As Enter the file name in the File Name block and click Save Saving the file will allow for quick and easy reprogramming of units Pro...

Page 5: ...p may be triggered by any input event if programmed to do so For example if a long press on the Mode Input is not assigned to a function it may be configured to generate the error beep Beep Options Mo...

Page 6: ...using a trunking system This will cause the unit to hold off transmitting the ANI until it has received a channel acquisition acknowledgement from the radio Key Up Delay This sets the amount of time t...

Page 7: ...and 5 Tone formats and sets the length of each tone Tone Gap Duration This field only applies to DTMF and sets the length of the gap between tones Fleet ID This field only applies to FleetSync and se...

Page 8: ...t the repeat interval until canceled Transmit Count This sets the number of times the ENI will be sent Repeat Interval This sets the time between ENI transmissions PTT Resets Cancels ENI If selected p...

Page 9: ...erate a constant tone to alert the user the ENI is about to be transmitted Power up with Lone Worker on If checked the unit will be in Lone Worker mode when the radio is turned on This eliminates the...

Page 10: ...pe Select whether the switch is Momentary or Latched for Lone Worker on off and reset Mode Active Polarity Select the active polarity of the mode switch Mode Debounce If checked the unit will require...

Page 11: ...ive low or active high to start recording the received audio COR Debounce If checked the unit will require a continuous active state for 30 msec before accepting the COR PTT Active Polarity This sets...

Page 12: ...s whether the unit looks for an active low or active high to trigger an emergency ANI Emergency Debounce If checked the unit will require a continuous active state for 30 msec before accepting the Eme...

Page 13: ...to indicate a trunked channel has been established Tones Beep Volume Adjust the slider for the desired beep volume This level is expressed as a percentage of max voice audio level Tones Over The Air S...

Page 14: ...14 Please see the Audio Levels Alignment section for details on this tab...

Page 15: ...the radio unit These measurements must be taken within 15 seconds of powering on the unit This is because the unit may enter power saving mode after that time Measurements made while the unit is in po...

Page 16: ...easurement for each of the audio hookup points Adjust the slider bar such that the value appearing in the appropriate column matches what was measured as closely as possible Midian recommends the foll...

Page 17: ...osing the option board cover and remove the cover Remove the dummy board from the radio and replace with the unit Replace the option board cover and battery The unit requires this radio have firmware...

Page 18: ...rom Vertex onto the options connector per Vertex s instructions Then plug the unit onto the FIF 7A Replace the cover of the radio The unit requires firmware version 2 02 or higher in the VX 4000 The V...

Page 19: ...annel basis On this screen the SQ column must have a figure greater than 0 Download the program to the radio VX 450 VX 460 For the VX 450 VX 460 radio programming software CE 115 v1 01 or higher must...

Page 20: ...VP 35 Under the Common heading select Key Function to set which key will control the Emergency ANI or Lone Worker on off Program the desired button to Option SW1 or Option SW2 Option SW1 is momentary...

Page 21: ...0 or higher or CE 49 v3 3 0 0 or higher must be used For the VX 5500 VX 6000 radio programming software CE 49 v3 3 0 0 or higher must be used Read the radio with the option board installed Select Com...

Page 22: ...erate warning tones to indicate to the user that the Lone Worker feature is about to send an ENI if the unit does not see PTT or Lone Worker Reset activity If the Transmit Delay time then expires the...

Page 23: ...02 COC49 PID101 PID102 COD1 PID201 PID202 COD2 PID301 PID302 COD3 PID401 PID402 COD4 PID501 PID502 COD5 PIP101 COP1 1 PIP102 COP1 2 PIP103 COP1 3 PIP104 COP1 4 PIP105 COP1 5 PIP106 COP1 6 PIP107 COP1...

Page 24: ...This page intentionally left blank...

Page 25: ...COR35 PAR3602 PAR3601 COR36 PAR3901 PAR3902 COR39 PAR4002 PAR4001 COR40 PAR4101 PAR4102 COR41 PAR4202 PAR4201 COR42 PAR4302 PAR4301 COR43 PAR4402 PAR4401 COR44 PAR4502 PAR4501 COR45 PAR4602 PAR4601 CO...

Page 26: ...02 PAP305 PAP303 PAP306 PAP304 C O P 3 P A P 4 0 1 P A P 4 0 2 P A P 4 0 5 P A P 4 0 3 P A P 4 0 6 P A P 4 0 4 C O P 4 C O t b 0 s c h 2 P A V O 2 0 0 P A V O 2 0 4 P A V O 2 0 6 P A V O 2 0 3 P A V O...

Reviews: