Midea WWK08CW71E User Manual Download Page 11

10

AIR CONDITIONER FEATURES

O

O

Shows the set temperature in    C  or    F . While on 
Fan only mode,it shows the room temperature.

DISPLAYS:

Error codes:
AS-

Room temperature sensor error-Unplug the unit 

       and plug it back in.If error repeats, call for service.
       NOTE:In Fan only mode,it will display L0  or  HI .

ES-

Evaporator temperature sensor error-Unplug the 

       unit and plug it back in. If error repeats, call for 
       service.

After the unit has stopped,  it can not be restarted 
operation in the first 3 minutes. This is to protect the 
unit. Operation will automatically start after 3 minutes.

DISPLAYS:

Displayed in COOL mode operation.

Displayed in FAN mode operation. 

Displayed in ENERGY SAVER mode operation. 

Displayed in WiFi feature operation. 

Displayed in CHECK FILTER mode operation. 

L0

Displayed when room temperature is lower

O

O

than 0 C/32 F.

HI

Displayed when room temperature is higher

O

O

than 37 C/99 F.

Special features:

Wait 3 minutes before resuming operation

Auto Restart

If the unit turns off unexpectedly due to the power 
cut, it will restart with the previous function setting 
automatically when the power resumes. 

Energy Saver feature

This function is available on COOL automatically. The 
fan will continue to run for 3 minutes after the 
compressor shuts off.The fan then cycles on for 2 
minutes at 10 minute intervals until the room 
temperature is above the set temperature, at which 
time the compressor turns back on and Cooling Starts.

Timer: auto start/stop feature

Set the auto start/stop unit time no matter what the
unit is on or off. 

Turning the unit ON or OFF at any time 

will cancel the Auto Start/Stop timed program.

Swing  feature

Press the SWING button of the remote controller for
2 seconds to start louver auto swing feature. Short
press the button to use to change the louver movement
and set the desired air flow direction. 

WiFi feature

For the first time to use WiFi feature, press the WiFi
button for 5 seconds to turn off the unit and initiate the
WiFi connection mode. The LED DISPLAY shows AP 
for 1 second and off for 2 seconds circularly to indicate
you can set WiFi connection. If connection is success-
ful within 8 minutes the unit will exit WiFi connection 
mode automatically and the WiFi indicator illuminates. 
If connection is failure within 8 minutes, the unit exits 
WiFi connection mode automatically.  

Auto Defrost

When frost builds up on the evaporator coils, the 
compressor will cycle off and the fan will continue 
to run until the frost disappears.

NOTE

: If an operation has not been selected within 

10 seconds, the display will dim. Display will brighten 
again when an operation is selected.  

NOTE

: When the louver is horizontal, the unit will be

perfect cooling efficiency.

CAUTION

Never operate the louver manually.

 
    Note   during the network configuration process, do 
    not try using the remote control or the controls on the 
    front panel of the air conditioner, as they will be 
    inoperative.  You may use the remote control and front 
    panel buttons again after the network configuration 
    process is complete (usually 8   10 minutes)
    

Summary of Contents for WWK08CW71E

Page 1: ...ly and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR...

Page 2: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Page 3: ...contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth Ensure that the installation brac...

Page 4: ...n removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils The complete electical rating of your new room air condition...

Page 5: ...o not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special...

Page 6: ...CORDION PANELS 3 3 NOTE Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of 5 16 This is necessary for proper condensed water utilization and drainage If you...

Page 7: ...ner frame is against the window sill Fig 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about O H Fig 5 tilted about 3 to 4 downward...

Page 8: ...e optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below Step 1 After the unit is installed to the window measure the inner width of t...

Page 9: ...lock Remove the R1 Panel and close slide side panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaining water while lifting unit...

Page 10: ...ing or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser during normal operation may cause pingi...

Page 11: ...ooling Starts Timer auto start stop feature Set the auto start stop unit time no matter what the unit is on or off Turning the unit ON or OFF at any time will cancel the Auto Start Stop timed program...

Page 12: ...hake excess water from the filter Be sure the filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean Take down the low front panel Low front panel Take out the...

Page 13: ...coil set FAN ONLY mode Compressor stopped when changing modes Wait for 3 minutes after set to the COOL mode 12 Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Unit...

Page 14: ...Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructed Remove obstruction Room too cold Set temperature too l...

Page 15: ...Midea...

Page 16: ...90 90 90...

Page 17: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Reviews: