background image

”key for along time to quickly set the scheduled time

and the scheduled time will 

[Inspection before start]

1.The power cord shall not be damaged or fractured.

2.Please verify the rated current of the power socket is in line with the requirements 

in the table above and is equipped with a safety grounding device before use; oth-

erwise, replace the socket.

[Operating Instructions]
<

Work/Standby

>:

Plug in the power,the buzzer will “beep” for along time,press the 

power key “   ” to enter the  heating working state,and then press the 

power key “    ” to enter the standby state.

<Gear selection>: For work status, press “

” key to select one of work modes 

such as high gear, medium gear and low gear .

OPERATING INSTRUCTION

<Temperature Setting>:Under the working status,press and hold the“

  

”key or“   ”key 

to set the temperature,press and hold the“

  

”key or the“   ”key to quickly set the tem-

perature;after setting the temperature,have non-operation for 5 seconds,exit the tem-

perature  setting screen.

-

<Scheduled work>:Tap the timer key"   " in standby mode to enter the scheduled 

work setting screen. Press“

  

”key or“

  

”key to set the scheduled time, press“

  

”key 

or“

  

<Scheduling standby>:Under the working status,press the timer key"   "to enter the 

scheduling standby setting screen.Press“

  

”key or“

  

”key to set the scheduling time,

<Memory function>:When started up the machine again and it will operate according 

to the status before the last standby.

press“

  

”key or“

  

”key for along time to quickly set the scheduling time,and the 

scheduling time is in the standby state to the machine.

A:the scope of scheduling is for 0~24hours,and press"

  

"key or"

  

"key each time to 

increase or decrease 1 hour.When the set value is 0H,press the"

  

"key to set the 

time for 24H.When the set value is 24H,press the"

  

"key,and the setting time is 

0H.When the set value is 0H,the scheduling is canceled. When the set value is not 

0H,the scheduling is started.Set the appointment time,press the timing key"  "key or 

"       "key,or without operation for 5 seconds,exit scheduling mode.

B:If the scheduling time isset,press the 

power button

"   "to enter the standby state and 

cancel the scheduling.

C:After the scheduling is started,press the scheduling key"  "to check the remaining 

time of the appointment and reset the scheduling time.During the scheduled time,the 

machine is shut down or started upunder temperature control,and the scheduled time 

is always normal,and free from down time.During the scheduled time,it is cleared 

incase of power failure

.

reach  the working status of the machine.

Summary of Contents for NY2009-20MR

Page 1: ...GD Midea Environment Appliances MFG Co Ltd No 28 Dong Fu Road Hesui East Industrial Area Dong Feng Town Zhongshan Guangdong 528425 P R China NY2009 20MR NY2311 20MR...

Page 2: ...1 2 3 8 4 5 6 3 3 8 3 8...

Page 3: ...7 8 9 10...

Page 4: ...1 2 1 2 1 3 2...

Page 5: ...1 2 Work Standby Gear selection Scheduled work Scheduling standby A 0 24 1 0H 24H 24H 0H 0H 0H 5 B...

Page 6: ...C Memory function Safety protection function Th 50 C 10 FF 1 Hz 75 50 C Shut down 50 C...

Page 7: ......

Page 8: ...1 2 3...

Page 9: ...ea Environment Appliances MFG Co Ltd No 28 Dong Fu Road Hesui East Industrial Area Dong Feng Town Zhongshan Guangdong 528425 P R China This product is only suitable for well insulated spaces or occasi...

Page 10: ...appli ance Cleaning and user maintenance shall not be made by children without supervision 4 The heater must not be located immediately below a socket outlet 5 Do not use this heater in the immediate...

Page 11: ...Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from...

Page 12: ...ounting hole of a set of caster assembly and install it on the screw of the caster pad plate at the end of the radiator fin and The other caster assembly is aligned to the screws mounted at the bottom...

Page 13: ...orking status press the timer key to enter the scheduling standby setting screen Press key or key to set the scheduling time Memory function When started up the machine again and it will operate accor...

Page 14: ...Safety protection function When the indoor ambient temperature Th exceeds 50 C under the standby or working state all out puts are turned off the buzzer prompts 10 long beeps the digital screen displa...

Page 15: ...OL Instructions for remote control unit Button function are basically consistent with the operation panel of the body and the remote control unit cannot control the combination key Timer key Function...

Page 16: ...he radiating efficiency 2 Disconnect electricity supply and allow radiator to cool wipe out dust with a soft damp cloth Do not use detergent or abrasives 3 Do not scrap the surfaces of flanges with sh...