background image

EasyCool Window

version A - 04 - 2017

MWA12CR71

MWA10CR71

MWA08CR71

MWA06CR71

www.midea.com

USER MANUAL

en

MWA

Warning notices: Before
using this product, please
read this manual carefully
and keep it for future
reference.

The design and
specifications are subject to
change without prior notice
for product improvement.
Consult with your dealer or
manufacturer for details.

Rated voltage: 115V
Rated power: 490 ~ 1000W
Frequency: 60Hz
Capacity: 6000 ~ 12000BTU/h

Summary of Contents for MWA06CR71

Page 1: ...Before using this product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult wi...

Page 2: ...he authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intented for use by young children or infirm pers...

Page 3: ...leakage from another appliance Do not operate or stop the unit by inserting or pulling out the power plug Do not operate with wet hands or in very humid enviroments It may cause electric shock Do not...

Page 4: ...uld cause injury Do not clean the air conditioner with water Water may enter the unit and degrade the insulation It may cause an electric shock Do not put a pet or house plant where it will be exposed...

Page 5: ...to the rating when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped wit...

Page 6: ...ges 4 The power supply cord is now supplying electricity to the unit On some products this it also indicated by a light on the plug head Safety Precautions NOTES Do not use this device to turn the uni...

Page 7: ...e level Hi Med Lo dB A 56 4 54 1 51 9 58 4 55 8 53 7 59 5 58 5 57 60 5 59 3 57 7 Plug type 5 15P 5 15P 5 15P 5 15P Control type Remote Control Remote Control Remote Control Remote Control Operating te...

Page 8: ...In front of the unit you may hear the sound of rushing air being moved by the fan High Pitched Chatter Modern compressors may have a high pitched sound during cooling cycle Vibration Unit may vibrate...

Page 9: ...unit is used in a condition with a relative humidity over 80 there will be condensed water on the surface of the unit Performance may be reduced outside of these operating temperatures Before you beg...

Page 10: ...omatically to hit the temperature set point you choose In this mode the fan speed cannot be adjusted it starts automatically at a speed according to the room temperature Operating on FAN mode Use this...

Page 11: ...ress or hold either left or right button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until sta...

Page 12: ...t from one to the other press and hold the left or right Temp Timer buttons at the same time for 3 seconds The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed See Fig...

Page 13: ...d rear coils WARNING Before You Begin Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordianaces...

Page 14: ...foam 1 Top Rail Hardware Top Rail 1 3 8 Screws 4 1 PREPARE THE WINDOW Lower sash must open sufficiently to allow a clear vertical opening H of following size see Table 1 Side louvers and the rear of...

Page 15: ...panel down Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet How To Install NOTE Top rail and side panels at each side are offset to provide the prop...

Page 16: ...Once the panel has been installed on the side of the cabinet make sure it sits securely inside the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the top an...

Page 17: ...d by Storm Window Removing AC From Window Add wood as shown in Fig 10 or remove storm window before air conditioner is installed If storm window frame must remain be sure the drain holes or slots are...

Page 18: ...t may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or p...

Page 19: ...cooling but room is too warm NO ice forming on cooling coil behind decorative front Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature...

Page 20: ...to the indoor unit Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is expo...

Page 21: ...it b The main unit does not respond to a command issue by the remote control Eletronic Display Protect the remote control from high temperatures and keep away from radiation exposure Keep the control...

Page 22: ...te the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consu...

Page 23: ......

Page 24: ......

Reviews: