Pr
oduct Featur
es
Page 77
which, the unit exits this mode and switches off.
• The timer setting is available in this mode.
1.11 Auto-Restart
• The indoor unit has an auto-restart module that
allows the unit to restart automatically. The module
automatically stores the current settings (not including
sleep mode) and, in the case of a sudden power
failure, will restore those setting automatically within 3
minutes after power returns.
• If the unit was in forced cooling mode, it will run in
this mode for 30 minutes and turn to auto mode with
temperature set to 24
℃
.
• If there is a power failure while the unit is running, the
compressor starts 3 minutes after the unit restarts. If
the unit was already off before the power failure, the
compressor starts 1 minute after the unit restarts.
1.12 Follow Me (Optional)
• If you press “Follow Me” on the remote, the indoor
unit will beep. This indicates the follow me function is
active.
• Once active, the remote control will send a signal
every 3 minutes, with no beeps. The unit automatically
sets the temperature according to the measurements
from the remote control.
• The unit will only change modes if the information
from the remote control makes it necessary, not from
the unit’s temperature setting.
1.13 Drain Pump Control (Optional)
• Use the water-level switch to control drain pump.
• The system checks the water level every 5 seconds.
• When the A/C operates in cooling (including auto
cooling) or forced cooling mode, the pump begins
running immediately and continuously until cooling
stops.
• If the water level increases up to the control point,
the LED displays an alarm code and the drain pump
opens and continually monitors the water level. If
the water level falls and LED alarm code is no longer
displayed (drain pump close delay is 1 minute), the
unit goes back into its last mode. Otherwise, the
entire system (including the pump) stops and the
LED displays an alarm again after 3 minutes.
2. Remote Controller Functions
2.1 Infrared Wireless Remote Controller
2.1.1 RG51Q1/BGE
(Standard)
Remote Controller Specifications
Model
RG51Q1/BGE
Rated Voltage
3.0V (Dry batteries R03/
LR03×2)
Reaching Distance
8m (when using 3.0
voltage, it Gets 11m)
Environment Temperature
Range
-5
℃
~60
℃(
23
℉
~140
℉)
Buttons and Functions
1. TEMP UP
: Push this button to increase the indoor
temperature setting in 1
℃
increments to 30
℃
2. TEMP DOWN : Push this button to decrease the
indoor temperature setting in 1
℃
increments to 17
℃.
3. MODE: Once pressing, running mode will be selected in
the following sequence: