16
7. Installation details
7.1 Wrench torque sheet for installation
Outside diameter
Torque
mm
inch
Kgf.m
Ф
6.35
1/4
1.8
Ф
9.52
3/8
4.2
Ф
12.7
1/2
5.5
7.2 Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Grade
Unit
9K
12K
18K
mm
2
1.5
1.5
2.5
7.3 Pipe length and the elevation
Pipe size
Capacity
Btu/h
Gas
Liquid
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
9k
3/8
’’
(
Ф
9.52)
1/4
’’
(
Ф
6.35) 5
8
20
30
12k
1/2
’’
(
Ф
12.7)
1/4
’’
(
Ф
6.35) 5
10
25
30
18k
1/2
’’
(
Ф
12.7)
1/4
’’
(
Ф
6.35) 5
10
25
30
Caution:
Capacity is based on standard length and maximum allowance length is base of reliability.
Oil trap should be installed per 5-7 meters.
7.4 Air purging of the piping and indoor unit
Required tools:
Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak
detector.