Service manual
16
7.4
Air purging of the piping and indoor unit
Required tools:
Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak
detector.
Note:
The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration piping,
it will affect the compressor, reduce the cooling capacity, and could lead to a malfunction of unit.
Be sure, using a torque wrench to tighten the service port cap (after using the service port), so that
it prevents the gas leakage from the refrigeration cycle.
Procedure
Recheck the piping connections.
Open the valve stem of the 2-way valve
counterclockwise approximately 90’, wait 10
seconds, and then set it to closed position.
Be sure to use a hexagonal wrench to operate
the valve stem
Check for gas leakage.
Check the flare connection for gas leakage
Purge the air from the system.
Set the 2-way valve to the open position and
remove the cap from the 3-way valve’s service
port.
Using the hexagonal wrench to press the
valve core pin, discharge for three seconds
and then wait for one minute.
Use torque wrench to tighten the service port
cap to a torque of 1.8 kg.m. (18n.m)
Set the 3-way valve to the opened position.
Mounted the valve stem nuts to the 2-way and
3-way valves.
Check for gas leakage.
At this time, especially check for gas leakage
from the 2-way and 3-way stem nuts, and from
the service port.
Caution:
If gas leakage is discovered in step (3) above,
take the following measures.
If the leaks stop when the piping connections
are tightened further, continue working from
step (4).
If the gas leaks do not stop when the
connections are retightened, repair the
location of the leak, discharge all of the gas
through the service port, and then recharge
with the specified amount of gas from a gas
cylinder.
Summary of Contents for MSR1-09CR-NB6
Page 1: ...Cover MSR1 09CR NB6 MSR1 09HR NB6 MSR1 12CR NB4 MSR1 12HR NB4 MSR1 18CR NB4 MSR1 18HR NB4...
Page 12: ...Service manual 9 4 Refrigerant cycle diagram Cooling only Heat pump mode...
Page 15: ...Service manual 12 Outdoor MSR1 09HR NB6 MSR1 12HR NB4 6 Indoor MSR1 18CR NB4 6...
Page 16: ...Service manual 13 Outdoor MSR1 18CR NB4 6 Indoor MSR1 18HR NB4 6...