53
3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
Normal resistance value
Digital tester
Normal resistance value
(+)Red
(-)Black
∞
(Several M
Ω
)
(+)Red
(-)Black
∞
(Several M
Ω
)
P
N
U
N
U
V
V
W
W
(+)Red
4.Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
RPG20E(YKFG-20-4-5)
RPG28D(YKFG-28-4-1)
RPG45C(YKFG-45-4-22)
Black - Red
388
Ω±
8% (20
℃
)
(Brand: Weiling)
260
Ω±
8% (20
℃
)
(Brand: Weiling)
168
Ω±
8% (20
℃
)
(Brand: Weiling)
White - Black
360
Ω±
8% (20
℃
)
(Brand: Weiling)
385
Ω±
8% (20
℃
)
(Brand: Weiling)
141
Ω±
8% (20
℃
)
(Brand: Weiling)
Summary of Contents for MSMBB-12CRDN1-MP0W
Page 7: ...5 2 2 Part names of Indoor Outdoor units ...
Page 9: ...7 For MSMBB 12CRDN1 MP0W For MSMBC 18CRDN1 MP0W For MSMBD 22CRDN1 MP5W ...
Page 13: ...11 MOF1 22CDN1 MP5W ...
Page 25: ...23 ...
Page 32: ...30 MOF1 22CDN1 MP5W ...
Page 36: ...34 9 2 3 Zero crossing detection error diagnosis and solution E2 ...
Page 39: ...37 supply or 50V 115V power supply the PCB must has problems and need to be replaced ...
Page 45: ...43 P W N U ...
Page 46: ...44 N V N W ...