R410A Rooftop Package Unit 60Hz
MCAC-RTSM-2014-03
34
Typical rooftop application with frame:
SU
PP
LY
RE
TU
RN
15.4 Ground Level -- Horizontal Units
For ground level installations, the unit should be positioned on a pad the size of the unit or larger. The unit
must be level on the pad. The pad must not come in contact with the structure. Be sure the outdoor portion of
the supply and return air ducts are as short as possible.
Installation according to the following procedure:
1) Place the unit on the pad.
2) Attach the supply and return air ducts to the unit.
3) Insulate any ductwork outside of the structure with at least 2 inches of insulation and weatherproof. There
must be a weatherproof seal where the duct enters the structure.
4) Complete the installation according to the instructions.
Typical ground level application:
≥
30
00
OV
ER
HE
AD
CL
EA
RA
NC
E
≥800
≥800
TO SERVIC
E COIL
AND CLEAN
FILTER
TO SERVIC
E ELECTRI
CAL
CONTROLS
AND INDOO
R BLOWER
≥3
00
≥5
00
≥
10
0
TO
SUP
PLY
AIR
FOR
COI
L
TO
CON
NEC
T
DRA
IN
PIP
ING
Summary of Contents for MRC-36CWN1-V10
Page 13: ...MCAC RTSM 2014 03 R410A Rooftop Package Unit 60Hz 13 7 Dimensional Drawing 3 5ton ...
Page 14: ...R410A Rooftop Package Unit 60Hz MCAC RTSM 2014 03 14 8 Wiring Diagram 8 1 MRC 36CWN1 V10 ...
Page 15: ...MCAC RTSM 2014 03 R410A Rooftop Package Unit 60Hz 15 8 2 MRC 48CWN1 V10 ...
Page 16: ...R410A Rooftop Package Unit 60Hz MCAC RTSM 2014 03 16 8 3 MRC 60CWN1 V10 ...
Page 17: ...MCAC RTSM 2014 03 R410A Rooftop Package Unit 60Hz 17 MRC 60CWN1 X10 ...