11.1 Indoor Unit Error Display
Operation lamp Timer lamp Display
LED STATUS
☆
1 time
X E0
Indoor unit EEPROM parameter error
☆
2 times
X E1
Indoor / outdoor units communication error
☆
3 times
X
E2
Zero-crossing signal error
☆
4 times
X
E3
Indoor fan speed has been out of control
☆
5 times
X
E4
Open circuit or short circuit of indoor room temperature
sensor
☆
6 times
X
E5
Open circuit or short circuit of evaporator coil temperature
sensor
☆
7 times
X
EC
Refrigerant Leakage Detection
☆
2 times
O
F1
Open circuit or short circuit of outdoor ambient
temperature sensor
☆
3 times
O
F2
Open circuit or short circuit of condenser coil temperature
sensor
☆
4 times
O
F3
Open circuit or short circuit of compressor discharge
temperature sensor
☆
5 times
O
F4
Outdoor unit EEPROM parameter error
☆
6 times
O F5
Outdoor
fan
speed
has been out of control
☆
1 times
☆
P0
IPM malfunction or IGBT over-strong current protection
☆
2 times
☆
P1
Over voltage or over low voltage protection
☆
3 times
☆
P2
High temperature protection of compressor top diagnosis
and solution (only for 18k,24k models)
☆
5 times
☆
P4
Inverter compressor drive error
O
(